PLC⌕
Janitza

52.22.063

UMG 96RM-E – Multi-functional power analyzer with Ethernet and RCM
52.22.063

Janitza 52.22.063 — UMG 96RM-E – Multi-functional power analyzer with Ethernet and RCM. Janitza has announced its discontinuation (last order 2027-08-31). PartnerPLC supplies new, surplus and discontinued Janitza parts — request a quote for price, condition and lead time.

<p>Janitza 52.22.063 — UMG 96RM-E – Multi-functional power analyzer with Ethernet and RCM. Janitza has announced its discontinuation (last order 2027-08-31).</p><p>The multi-functional UMG 96RM-E power analyzer monitors and measures residual currents whilst enabling the measurement and calculation of electrical variables.</p><h3>Universal meter</h3><ul><li>Operating current monitoring for general electrical parameters</li><li>High transparency through a multi-stage and scalable measurement system in the field of energy measurement</li><li>Acquisition of events through continuous measurement with 200 ms high resolution</li></ul><h3>RCM device</h3><ul><li>Continuous monitoring of residual currents (Residual Current Monitor, RCM)</li><li>Alarming in case a preset threshold fault current reached</li><li>Near-realtime reactions for triggering countermeasures</li><li>Permanent RCM measurement for systems in permanent operation without the opportunity to switch off</li></ul><h3>Energy measurement device</h3><ul><li>Continuous acquisition of the energy data and load profiles</li><li>Essential both in relation to energy efficiency and for the safe design of power distribution systems</li></ul><h3>Harmonics analyser / event recorder</h3><ul><li>Analysis of individual harmonics for current and voltage</li><li>Prevention of production downtimes</li><li>Significantly longer service life for equipment</li><li>Rapid identification and analysis of power quality fluctuations by means of user-friendly tools (GridVis®)</li></ul><h3>Extensive selection of tariffs</h3><ul><li>7 tariffs each for effective energy (consumption, delivery and without backstop)</li><li>7 tariffs each for reactive energy (inductive, capacitive and without backstop)</li><li>7 tariffs for apparent energy</li><li>L1, L2 and L3, for each phase</li></ul><h3>Highest possible degree of reliability</h3><ul><li>Continuous leakage current measurement</li><li>Historical data: Long-term monitoring of the residual current allows changes to be identified in good time, e.g. insulation faults</li><li>Time characteristics: Recognition of time relationships</li><li>Prevention of neutral conductor carryover</li><li>RCM threshold values can be optimized for each individual case: Fixed, dynamic and stepped RCM threshold value</li><li>Monitoring of the CGP (central ground point) and the sub- distribution panels</li></ul><h3>Analysis of fault current events</h3><ul><li>Event list with time stamp and values</li><li>Presentation of fault currents with characteristic and duration</li><li>Reproduction of phase currents during the fault current surge</li><li>Presentation of the phase voltages during the fault current surge</li></ul><h3>Analysis of the harmonic fault current components</h3><ul><li>Frequencies of the fault currents (fault type)</li><li>Current peaks of the individual frequency components in A and %</li><li>Harmonics analysis up to 40th harmonic</li><li>Maximum values with real-time bar display</li></ul><p>PartnerPLC supplies new, surplus and discontinued Janitza parts — request a quote for price, condition and lead time.</p>

BrandJanitza
Lifecycle statusactive

Datasheet ↗

Not currently in stock

Price on request
Request sourcing Ask a question