6500-01-*-PNO-LNO
6500 Series Control Unit, Type Ex pxb and Ex pyb. 6500 series Ex pxb and Ex pyb purge and pressurization system. Operating mode: user programmable. Series: 6500. System: Ex pxb Purge , Ex pyb Purge. N...
6500 Series Control Unit, Type Ex pxb and Ex pyb. 6500 series Ex pxb and Ex pyb purge and pressurization system. Operating mode: user programmable. Series: 6500. System: Ex pxb Purge , Ex pyb Purge. Number of volume exchanges: 5 to 19. Hazardous environment: gas, dust, gas and dust. Safety Integrity Level (SIL): SIL 2. Rated voltage: 100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC. Connection: EPCU: Terminal blocks and grounding screwUIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 metersInput type: intrinsically safe. Physical: Bluetooth® 4.1. Transmitter frequency: 2.4 ... 2.4835 GHz. Transmitter radiated power: -19 ... 7.5 dBm. Sensitivity: -92.5 dBm at 0.1 % BER. Detection range: 100 m in air. Antenna: PCB. Bluetooth: declaration ID: D037849. Input I: Voltage free contact or namur proximity sensor. Input typeIntrinsically Safe, Ex ib: . Input type: Intrinsically Safe, Ex ib. Input II: (1) 2-wire, PT100 RTD. Input typeIntrinsically Safe, Ex ib: . Input type: Intrinsically Safe, Ex ib. Output I: AUX. Output typeVoltage free contact outputs, SPDT configurationInrush current2 AContact loading2 A @ 240VAC, resistive, 2 A @ 24VDC: . Output type: Voltage free contact outputs, SPDT configuration. Inrush current: 2 A. Contact loading: 2 A @ 240VAC, resistive, 2 A @ 24VDC. Output II: Enclosure. Output typeVoltage free contact outputs, 2 N.O. configurationInrush current8 AContact loading8A @ 240 V AC, resistive up to 60 °C 8A @ 24 V DC up to 60 °C 5A @ 240 V AC, resistive, 60 to 70 °C 5A @ 24 V DC up to 60 to 70 °CFuseExternal fusing is required at no more than 11 amps/1500 A breaking current: . Output type: Voltage free contact outputs, 2 N.O. configuration. Inrush current: 8 A. Contact loading: 8A @ 240 V AC, resistive up to 60 °C 8A @ 24 V DC up to 60 °C 5A @ 240 V AC, resistive, 60 to 70 °C 5A @ 24 V DC up to 60 to 70 °C. Fuse: External fusing is required at no more than 11 amps/1500 A breaking current. Output III: Digital valve When used with the 6500-MAN-DV-01, intrinsically safe Internal resistance 280 Ω. Output IV: Proportional valveWhen used with the 6500-MAN-PV-01, intrinsically safeCurrent: 4 to 20 mAMax. load: 300 Ω. Communication: HART via RS485 (PACTware available). Display elements: 2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons. LED indication: Safe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault Key: green - a button on the capacitive touch display has been activated. Momentary indication. Protective gas supply: instrument grade air or inert gas. Pressure requirement: For 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120 psig) regulatedFor 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulatedNote: max. pressure will depend on the vent model used.. Safe pressure: Gas: 0.82 mbar (0.33 in wc) Dust: 0.82 mbar (0.33 in wc) Gas+Dust: 0.82 mbar (0.33 in wc). Valve flows: Standard vent series: EPV-6500-*-01, 03, 05Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm).Minimum and maximum reading depending on type of vent and supply pressure.See datasheet for EPV-6500 series vent. Continuous (Dilution) vent series: EPV-6500-*-07, 08Readout on display is from 17 to 226 l/min (0.6 to 8 scfm) continuous reading.Maximum reading depending on type of vent and supply pressure.See datasheet for EPV-6500 series vent.. Ambient temperature: -20 ... 70 °C (-4 ... 158 °F). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Relative humidity: 5 ... 85 %, non-condensing. Vibration resistance: 5 ... 100 Hz , 1 g, 12 m/s2, all axes. Impact resistance: 30 g, 11 ms, all axes. Connection type: See mounting in 6500 manual and cable gland requirements. Cable gland: Cable gland requirement: cable glands are not included. Customer can supply their own approved glands or use one of the 6500-CBLG-... cable gland kits.I.S.cable glands: requires (5) M12 approved cable glandsPower cable glands: requires (2) M16 and (2) M12 approved cable glands. Degree of protection: IP66. Material: UIC display: Makrolon FI cover and A380 Aluminum anodized casingHousing: 316L stainless steelHardware: 316L stainless steel. Mass: approx. 5 kg (11.0 lbs). Dimensions: 6500-01-EXT1: 150 x 150 x 145 mm (5.9" x 5.9" x 5.7") 6500-01-PM01: 150 x 150 x 185 mm (5.9" x 5.9" x 7.3") 6500-01-PM02: EPCU: 150 x 150 x 145 mm (5.9" x 5.9" x 5.7"), UIC: 150 x 150 x 45 mm (5.9" x 5.9" x 1.8"). Height367.5 mmWidth183 mmDepth152.5 mm: . Height: 367.5 mm. Width: 183 mm. Depth: 152.5 mm. Certificate: DEMKO 16 ATEX 1640X. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-5:2015 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-31:2014: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-5:2015 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-31:2014. IECEx approval: IECEx UL 16.0003X. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |