CJ4-12GK-N
Capacitive sensor. Switching function: Normally open (NO), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindric...
Capacitive sensor. Switching function: Normally open (NO), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 20.0014X, Equipment protection level Gb: IECEx TUN 20.0014X, Equipment protection level Da: IECEx TUN 20.0014X, Equipment protection level Ga: TÜV 03 ATEX 2003 X, Equipment protection level Gb: TÜV 03 ATEX 2003 X. Switching function: Normally open (NO). Output type: NAMUR. Rated operating distance: 4 mm. Installation: non-flush. Assured operating distance: 0 ... 2.88 mm. Output type: 2-wire. Installation conditions: . A20 mmB80 mmC12 mmF70 mm: . A: 20 mm. B: 80 mm. C: 12 mm. F: 70 mm. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Operating voltage: 7 ... 12 V. Switching frequency: 0 ... 1 Hz. Current consumption: . Measuring plate not detected≤ 1 mAMeasuring plate detected≥ 2.4 mA: . Measuring plate not detected: ≤ 1 mA. Measuring plate detected: ≥ 2.4 mA. MTTFd: 3299 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx TUN 20.0014XEquipment protection level GbIECEx TUN 20.0014XEquipment protection level DaIECEx TUN 20.0014X: . Equipment protection level Ga: IECEx TUN 20.0014X. Equipment protection level Gb: IECEx TUN 20.0014X. Equipment protection level Da: IECEx TUN 20.0014X. ATEX approval: . Equipment protection level GaTÜV 03 ATEX 2003 XEquipment protection level GbTÜV 03 ATEX 2003 XEquipment protection level DaTÜV 03 ATEX 2003 X: . Equipment protection level Ga: TÜV 03 ATEX 2003 X. Equipment protection level Gb: TÜV 03 ATEX 2003 X. Equipment protection level Da: TÜV 03 ATEX 2003 X. FM approval: . Control drawing116-0165: . Control drawing: 116-0165. UL approval: cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP68. Cable: . Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.34 mm2LengthL2 m: . Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Length60 mmDiameter12 mm: . Length: 60 mm. Diameter: 12 mm. Use in the hazardous area: see instruction manuals
| Brand | Pepperl Fuchs |
| Lifecycle status | active |