F*-LBF-D1.32
Surge Protector. Surge protector, threaded, for installation via threaded inlet in field housing (Ex d), IP67, Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge...
Surge Protector. Surge protector, threaded, for installation via threaded inlet in field housing (Ex d), IP67, Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, Device coupler location: non-explosion hazardous area<BR>Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk. Design / Mounting: Outside installation. Installation in hazardous area: Zone 1. Rated voltage: 32 V. Nominal discharge current (8/20 µs): . per line10 kAtotal10 kA: . per line: 10 kA. total: 10 kA. Max. surge current (8/20 µs): 10 kA. Voltage protection level at max. rated current: . Line/Line58 VLine/Earth1700 V: . Line/Line: 58 V. Line/Earth: 1700 V. Voltage protection level at 1 kV/µsec: . Line/Line50 VLine/Earth1.2 kV: . Line/Line: 50 V. Line/Earth: 1.2 kV. Reaction time: . Line/Linemax. 1 nsLine/Earthmax. 100 ns: . Line/Line: max. 1 ns. Line/Earth: max. 100 ns. Capacitance: . Line/Line25 pFLine/Earth15 pF: . Line/Line: 25 pF. Line/Earth: 15 pF. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC/EN 60529. Fieldbus standard: IEC 61158-2. Surge protection: IEC 61643-21. Ambient temperature: -50 ... 80 °C (-58 ... 176 °F). Storage temperature: -50 ... 85 °C (-58 ... 185 °F). Core cross section: 1.3 mm2. Housing material: Stainless steel 1.4401/316. Degree of protection: IP00/IP67 if correctly installed. Mass: 160 g. Mounting: screw mounting. EU-type examination certificate: KEMA 04 ATEX 2318 X. Marking II 2G Ex db IIC T6...T5 Gb: . Marking: II 2G Ex db IIC T6...T5 Gb. Maximum values: . Rated voltage32 V: . Rated voltage: 32 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014. IECEx approval: . IECEx certificateIECEx KEM 09.0067XIECEx markingEx db IIC T6...T5 Gb: . IECEx certificate: IECEx KEM 09.0067X. IECEx marking: Ex db IIC T6...T5 Gb. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |