F2-JB-I*.*
Field Junction Box. Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk...
Field Junction Box. Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: Zone 1 - intrinsically safe trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installation. Design / Mounting: Outside installation. Installation in hazardous area: Zone 1 / Div. 1. Main cable (Trunk): . Cable entry typeCable glandConnectioninput (Trunk IN): terminals 1+, 2-, 3soutput (Trunk OUT): terminals 4+, 5-, 6sRated voltagemax. 35 V DCRated current3 A DC: . Cable entry type: Cable gland. Connection: input (Trunk IN): terminals 1+, 2-, 3soutput (Trunk OUT): terminals 4+, 5-, 6s. Rated voltage: max. 35 V DC. Rated current: 3 A DC. Outputs: . Number of outputssee table "Technical data depending on model"Cable entry typeCable glandConnectionSpur 1: terminals 10+, 11-, 12sSpur 2: terminals 13+, 14-, 15sSpur 3: terminals 16+, 17-, 18sSpur 4: terminals 19+, 20-, 21sSpur 5: terminals 22+, 23-, 24sSpur 6: terminals 25+, 26-, 27sSpur 7: terminals 28+, 29-, 30sSpur 8: terminals 31+, 32-, 33sRated voltagesee main cableRated currentsee main cable: . Number of outputs: see table "Technical data depending on model". Cable entry type: Cable gland. Connection: Spur 1: terminals 10+, 11-, 12sSpur 2: terminals 13+, 14-, 15sSpur 3: terminals 16+, 17-, 18sSpur 4: terminals 19+, 20-, 21sSpur 5: terminals 22+, 23-, 24sSpur 6: terminals 25+, 26-, 27sSpur 7: terminals 28+, 29-, 30sSpur 8: terminals 31+, 32-, 33s. Rated voltage: see main cable. Rated current: see main cable. Electromagnetic compatibility: . Directive 2004/108/ECEN 61326-1:2006: . Directive 2004/108/EC: EN 61326-1:2006. Electromagnetic compatibility: NAMUR NE 21, EN 61326. Degree of protection: IEC/EN 60529. Fieldbus standard: IEC 61158-2. Climatic conditions: DIN IEC 721. Ambient temperature: see table. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: screw terminal , fixed. Core cross section: up to 2.5 mm2. Cable diameter: . Main cable (Trunk)5 ... 10 mm: . Main cable (Trunk): 5 ... 10 mm. Housing: 258 mm x 114 mm x 84 mm (without cable glands). Housing material: Aluminum. Degree of protection: IP67. Mass: 1800 g. Mounting: wall mounting. Main cable (Trunk): only for connection to intrinsically safe fieldbus circuits. Maximum values: . Voltage Uimax. 35 VCurrent Iimax. 3 A: . Voltage Ui: max. 35 V. Current Ii: max. 3 A. Directive conformity: Standards. Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-11:2012
| Brand | Pepperl Fuchs |
| Lifecycle status | active |