FB7204B3
Universal Input/Output (HART). 4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Fie...
Universal Input/Output (HART). 4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication. Occupied slots: 1. Connection: backplane bus. Rated voltage: 12 V DC , only in connection with the power supplies FB92**. Power dissipation: 2 W. Power consumption: 3 W. Connection: backplane bus. Interface: manufacturer-specific bus to standard com unit. Number of channels: 4. Suitable field devices: . Field devicepressure converterField device [2]flow converterField device [3]level converterField device [4]Temperature Converter: . Field device: pressure converter. Field device [2]: flow converter. Field device [3]: level converter. Field device [4]: Temperature Converter. Field device interface: . Connection2-wire transmitter: . Connection: 2-wire transmitter. Connection: terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-. Transmitter supply voltage: min. 15 V at 20 mA ; 21.5 V at 4 mA. Input resistance: 15 Ω. Line fault detection: can be switched on/off for each channel via configuration tool , configurable via configuration tool. Short-circuitfactory setting: > 21 mA Can be parameterized in the range 0 ... 22 mAOpen-circuitfactory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA: . Short-circuit: factory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA. Open-circuit: factory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA. HART communication: yes. HART secondary variable: yes. Number of channels: 4. Suitable field devices: . Field deviceProportional ValveField device [2]I/P convertersField device [3]on-site display: . Field device: Proportional Valve. Field device [2]: I/P converters. Field device [3]: on-site display. Connection: terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-. Current: 0 ... 20 mA short-circuit protected. Line fault detection: can be switched on/off for each channel via configuration tool , configurable via configuration tool. Short-circuitfactory setting: < 50 Ω configurable between 0 ... 26 mAOpen-circuitdeviation of preset output value > 0.5 mA: . Short-circuit: factory setting: < 50 Ω configurable between 0 ... 26 mA. Open-circuit: deviation of preset output value > 0.5 mA. Load: max. 750 Ω at 20 mA. HART communication: yes. HART secondary variable: yes. Watchdog: output off 0.5 s after serious fault. Number of channels: 4. Sensor interface: . Connection [2]volt-free contact: . Connection [2]: volt-free contact. Connection: terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-. Line fault detection: can be switched on/off for each channel via configuration tool. Connectionmechanical switch with additional resistors (see connection diagram)Short-circuit> 7 mAOpen-circuit< 0.1 mA: . Connection: mechanical switch with additional resistors (see connection diagram). Short-circuit: > 7 mA. Open-circuit: < 0.1 mA. Digital signals (active): . Switching point: ON> 2.1 mASwitching point: OFF< 1.2 mA: . Switching point: ON: > 2.1 mA. Switching point: OFF: < 1.2 mA. Number of channels: 4. Suitable field devices: . Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm: . Field device: Solenoid Valve. Field device [2]: audible alarm. Field device [3]: visual alarm. Connection: terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8-. Drive capability: 12 V / 22 mA. Internal resistor: 385 Ω. Current limit: 22 mA. Open loop voltage: min. 22.7 V. Line fault detection: can be switched on/off for each channel via configuration tool. Test current0.4 mAShort-circuit< 50 ΩOpen-circuit< 0.2 mA: . Test current: 0.4 mA. Short-circuit: < 50 Ω. Open-circuit: < 0.2 mA. Deviation: . After calibration0.1 % of the signal range at 20 °C (68 °F)Influence of ambient temperature0.1 %/10 K of the signal range: . After calibration: 0.1 % of the signal range at 20 °C (68 °F). Influence of ambient temperature: 0.1 %/10 K of the signal range. Resolution: 12 Bit (0 ... 26 mA). Refresh time: approx. 100 ms (4 channels). LED indication: Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode. Coding: optional mechanical coding via front socket. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2). Mass: approx. 425 g. Dimensions: . Height107 mmWidth28 mmDepth132 mm: . Height: 107 mm. Width: 28 mm. Depth: 132 mm. EU-type examination certificate: Presafe 19 ATEX 14057U. Marking II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I: . Marking: II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I. Supply: . VoltageUo27 VCurrentIo87 mAPowerPo575 mW (linear characteristic): Uo. Voltage: 27 V. Current: 87 mA. Power: 575 mW (linear characteristic). Output: Ex ia. VoltageUo27 VCurrentIo87 mAPowerPo575 mW (linear characteristic)Internal capacitanceCi12 nFInternal inductanceLi0 mH: Uo. Voltage: 27 V. Current: 87 mA. Power: 575 mW (linear characteristic). Internal capacitance: 12 nF. Internal inductance: 0 mH. Galvanic isolation: . Rated voltageUm250 V field circuits to control and supply circuitsInput/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 VOutput/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V: Um. Rated voltage: 250 V field circuits to control and supply circuits. Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Output/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012. ATEX approval: Presafe 19 ATEX 14057U. IECEx approval: . IECEx certificateIECEx PRE 19.0012UIECEx markingEx db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx PRE 19.0012U. IECEx marking: Ex db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I. System information: The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |