PLC⌕
Pepperl Fuchs

HD2-GTR-4PA

HD2-GTR-4PA
HD2-GTR-4PA

Gateway. Gateway module for fieldbus power hub for PROFIBUS PA to PRFIBUS DP Master communication, PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optiona...

Gateway. Gateway module for fieldbus power hub for PROFIBUS PA to PRFIBUS DP Master communication, PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting, IECEx approval, International, Europe, USA, Canada. Design / Mounting: Motherboard based. Installation in hazardous area: Zone 2 / Div. 2. Rated voltage: 19.2 ... 30 V DC. Rated current: 150 ... 95 mA. Power dissipation: 3 W. Number of segments: 4. PROFIBUS DP: . Connection9-pin Sub-D socketProtocolPROFIBUS DP V1: . Connection: 9-pin Sub-D socket. Protocol: PROFIBUS DP V1. LED Seg 1...4: red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error. LED PWR: green: Power on. LED DP/ERR: red 2 Hz flashing: DP error ; red: Hardware error. LED Red.: yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available. CH/PROFIBUS DP: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. PROFIBUS DP/Supply: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. CH/CH: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. All circuits/FE: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Low voltage: . Directive 73/23/EECEN 50178 (identical to EN 62103): . Directive 73/23/EEC: EN 50178 (identical to EN 62103). Galvanic isolation: IEC 62103. Electromagnetic compatibility: NE 21:2017 for simplex operating mode only. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Pollution degree: max. 2, according to IEC 60664. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 250 g. Dimensions: . Height106 mmWidth40 mmDepth128 mm: . Height: 106 mm. Width: 40 mm. Depth: 128 mm. Mounting: motherboard mounting. Certificate: TÜV 04 ATEX 2500 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. IECEx approval: . IECEx certificateIECEx TUN 13.0038XIECEx markingEx nA IIC T4 Gc: . IECEx certificate: IECEx TUN 13.0038X. IECEx marking: Ex nA IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question