PLC⌕
Pepperl Fuchs

HD2-GTR-4PA.PN

HD2-GTR-4PA.PN
HD2-GTR-4PA.PN

Gateway. Gateway module for fieldbus power hub for PROFINET to PROFIBUS PA communication, Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zon...

Gateway. Gateway module for fieldbus power hub for PROFINET to PROFIBUS PA communication, Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area<BR>Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk<BR>Division 2 - high-power trunk<BR>Division 1 - high-power trunk. Design / Mounting: Motherboard based. Installation in hazardous area: Zone 2 / Div. 2. Rated voltage: 19.2 ... 35 V SELV/PELV. Rated current: typ. 135 mA. Power dissipation: approx. 3.5 W. Number of segments: 4. Number of devices per segment: max. 32. Fieldbus type: PROFIBUS PA. Number of ports: 2. Protocol: PROFINET. Ethernet Interface: Connector plug , 2x RJ45. Transfer rate: 100 MBit/s. Redundancy: Ring (MRP) , System S2. LED ETH1 LINK 2: green: link status. LED ETH1 ACT: yellow: activity status. LED ETH2 LINK: green: link status. LED ETH2 ACT: yellow: activity status. LED ERR: red 2 Hz flashing: Ethernet error. LED Seg 1...4: red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error. LED PWR: green: Power on. LED DP/ERR: red 2 Hz flashing: DP error ; red: Hardware error. LED Red.: yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available. CH/PROFIBUS DP: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff. PROFIBUS DP/Supply: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff. CH/CH: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff. CH/Ethernet: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff. All circuits/FE: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff. Ethernet/Supply: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F) vertically mounted , -40 ... 70 °C (-40 ... 158 °F) horizontally mounted. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Pollution degree: max. 2, according to IEC 60664. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 250 g. Dimensions: . Height106 mmWidth40 mmDepth128 mm: . Height: 106 mm. Width: 40 mm. Depth: 128 mm. Mounting: motherboard mounting. Certificate: TÜV 15 ATEX 7735 X. Marking II 3 G Ex ec IIC T4 Gc: . Marking: II 3 G Ex ec IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018. IECEx approval: IECEx TUR 16.0007X. Approved forEx ec IIC T4 Gc: . Approved for: Ex ec IIC T4 Gc. Marine approval: pending. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question