HiC2871
Solenoid Driver. 1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Int...
Solenoid Driver. 1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 19 ... 30 V DC loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 12 V. Signal type: Digital Output. Safety Integrity Level (SIL): SIL 3. Connection: loop powered. Rated voltage: 19 ... 30 V DC loop powered. Power dissipation: < 1 W. Connection side: control side. Connection: SL1: 8a(+), 7a(-). Rated voltage: 19 ... 30 V loop powered. Current: ≤ 72 mA at Ui = 19 V, ≤ 50 mA at Ui = 30 V with 265 Ω output load≤ 45 mA at Ui = 19 V, ≤ 31 mA at Ui = 30 V with shorted output≤ 14 mA at Ui = 19 V, ≤ 11 mA at Ui = 30 V no load at output. Inrush current: ≤ 200 mA after 100 µs. Connection side: field side. Connection: SL2: 5a(+), 5b(-). Internal resistor: ≤ 238 Ω. Current: ≤ 45 mA. Voltage: ≥ 12 V. Open loop voltage: ≥ 22.7 V. Output signal: These values are valid for the rated operating voltage 19 ... 30 V DC.. Energized/De-energized delay: single operation: typ. 1.7 ms/50 µs; periodical: typ. 5 µs/50 µs. Display elements: LED. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2006For further information see system description.. Degree of protection: IEC 60529:2001. Protection against electrical shock: EN 61010-1:2010. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Mass: approx. 100 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Height106 mmWidth12.5 mmDepth128 mm: . Height: 106 mm. Width: 12.5 mm. Depth: 128 mm. Mounting: on termination board. Coding: pin 1 and 4 trimmed For further information see system description.. EU-type examination certificate: BASEEFA 06 ATEX 0171X. Marking II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C) Output[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo25.2 VCurrentIo110 mAPowerPo693 mW: . Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C). Output: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I. Voltage: 25.2 V. Current: 110 mA. Power: 693 mW. Input: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Certificate: PF 08 CERT 1048 X. Marking II 3G Ex nA IIC T4 Gc: . Marking: II 3G Ex nA IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . Control drawing16-534FM-12 (cFMus): . Control drawing: 16-534FM-12 (cFMus). IECEx approval: . IECEx certificateIECEx BAS 06.0031XIECEx marking[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I: . IECEx certificate: IECEx BAS 06.0031X. IECEx marking: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |