PLC⌕
Pepperl Fuchs

IC-KP2-2HB6-V15B

IC-KP2-2HB6-V15B
IC-KP2-2HB6-V15B

RFID evaluation unit. IDENTControl Compact RFID evaluation unit with interface for PROFIBUS DP. Number of read/write heads: max. 2alternatively 1 read/write head and 1 trigger sensor. UL File Number:...

RFID evaluation unit. IDENTControl Compact RFID evaluation unit with interface for PROFIBUS DP. Number of read/write heads: max. 2alternatively 1 read/write head and 1 trigger sensor. UL File Number: E87056. LED BUS: green: Slave is at state "Data Exchange" red: Bus error. LED Diag: No function. LEDs 1, 2: Status indicator for read/write headsgreen: command at read/write head activeyellow: approx. 1 second long, if command was successfully executed. LEDs CH1, CH2: green: read head detectedred: Configuration error. LED PWR/ERR: green: power onred: Hardware fault. Rotary switch: Address setting 00 ... 7E, FF (hexadecimal)BUS Address (high nibble): 0 ... 7, FBUS Address (low nibble): 0 ... F. Rated operating voltage: 20 ... 30 V DC , PELV. Ripple: ≤ 10 % at 30 V DC. Current consumption: ≤ 4 A incl. read/write heads. Power consumption: 2 W Without read/write heads. Galvanic isolation: basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff. Interface type: PROFIBUS. Physical: RS-485. Protocol: PROFIBUS DP acc. to EN 50170. Transfer rate: 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing. Interface type: Diagnostic Interface. Physical: RS 232. Protocol: ASCII. Transfer rate: 38.4 kBit/s. Electromagnetic compatibility: . Directive 2014/30/EUEN 61000-6-2 EN 61000-6-4: . Directive 2014/30/EU: EN 61000-6-2 EN 61000-6-4. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000: . Directive 2011/65/EU (RoHS): IEC/EN 63000. Degree of protection: IEC 60529. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Climatic conditions: air humidity max. 96 % Salt spray resistant to EN 60068-2-52. Shock and impact resistance: Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27. Degree of protection: IP67. Connection: Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M12 connector PROFIBUS: M12 connector, B-coded. Material: . Housingpowder coated aluminum: . Housing: powder coated aluminum. Installation: screw fixing. Mass: approx. 300 g. Dimensions: . Height42 mmWidth62 mmLength137 mm: . Height: 42 mm. Width: 62 mm. Length: 137 mm

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question