KC-LCD-48-1R-24VDC
Timer, Counter. Counter/Timer, Adding/subtracting via 2 separate inputs, Batch controller with 1 pre-selection, Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output sta...
Timer, Counter. Counter/Timer, Adding/subtracting via 2 separate inputs, Batch controller with 1 pre-selection, Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status, Display range and preselection range from -999999 up to 999999<br>Overflow will be evaluated correctly up to 1 decade, Operating voltage: 11 ... 30 V DC, Relay: changeover contact, Dimensions: 48 mm x 48 mm x 109.8 mm. Pre-selection: single. Data storage: > 10 years, EEPROM. Programming: keypad-driven menu. Type: 2-line, 2 x 6-digit LC display with leading sign. Display value: digit height 9 mm. Pre-selection: digit height 7 mm. Key interlock: via "high" potential at "LOCK" input. Decimal point: 0 to max 5 fractional digits. Scale factor: 0.0001 ... 99.9999. Reset: manually or external. Fusing: 11 … 30 V DC: T 0.2 A. Operating voltage: 11 ... 30 V DC. Power consumption: max. 4 W. Connection: Counter inputs: A and B Control/reset inputs: LOCK, RESET. Signal voltage: . High3.5 ... 30 V DCLow0 ... 2 V DC: . High: 3.5 ... 30 V DC. Low: 0 ... 2 V DC. Counting frequency: 30 Hz / 5 kHz. Minimum pulse duration: Control/reset inputs: static / 1 ms. Impedance: 10 kOhm. Count modes: . Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad),TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.),: . Pulse counter: Counting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad),. Timer: Time measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.),. Relay: changeover contact. Switching voltagemax. 250 V AC / 110 V DCSwitching currentmax. 3 A AC/DC, min. 30 mA DC,Switching powermax. 750 VA / 90 WMechanical life2 x 107 switching cyclesElectrical life5 x 104 cycles at 3 AResponse time< 15 ms pulse counter < 10 ms time counter: . Switching voltage: max. 250 V AC / 110 V DC. Switching current: max. 3 A AC/DC, min. 30 mA DC,. Switching power: max. 750 VA / 90 W. Mechanical life: 2 x 107 switching cycles. Electrical life: 5 x 104 cycles at 3 A. Response time: < 15 ms pulse counter < 10 ms time counter. Sensor supply: connected power supply is looped through,max. 50 mA. Directive conformity: . EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999: . EMC Directive 2004/108/EC: EN 61000-6-2:2005, EN 50295:1999. Standard conformity: . Emitted interferenceDIN EN 55011:2009, Class BMech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each directionShock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction: . Emitted interference: DIN EN 55011:2009, Class B. Mech. capacity: EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction. Shock and impact resistance: EN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction. Ambient temperature: -10 ... 50 °C (14 ... 122 °F). Storage temperature: -25 ... 75 °C (-13 ... 167 °F). Relative humidity: ≤ 93 % at 40 °C(noncondensing). Altitude: 0 ... 2000 m. Degree of protection: IP65 (front). Mass: approx. 117 g. Dimensions: 48 mm x 48 mm x 109.8 mm
| Brand | Pepperl Fuchs |
| Lifecycle status | active |