KCD2-RR2-Ex1
Resistance Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100,...
Resistance Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Signal: Resistance. Signal type: Analog input. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 3. Connection: Power Rail or terminals 9+, 10-. Rated voltage: 19 ... 30 V DC. Ripple: within the supply tolerance. Rated current: < 28 mA. Power consumption: 0.35 W (24 V and 1 mA sense current), 0.85 W (30 V and 10 mA sense current). Connection side: field side. Connection: terminals 1, 2, 3, 4. Line fault detection: yes , at Pt100. Lead resistance: ≤ 10 % of resistance value. Transmission range: 0 ... 10 mA. Available voltage: 7 V. Line fault detection: < 30 nA. Connection side: control side. Connection: terminals 5-, 7-, 6+, 8+. Current: 0 ... 10 mA. Available voltage: 0 ... 4.2 V. Fault signal: field voltage < 150 mV or > 4 V, depending on lead disconnected. Reverse polarity protection: for I < 10 mA or U < 20 V. Accuracy: 0.1 %. Deviation: Im ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable).. Influence of ambient temperatureIm ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm: . Influence of ambient temperature: Im ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm. Settling time: ≤ 5 ms. Rise time/fall time: ≤ 2 ms (10 ... 90%). Output/power supply: functional insulation, rated insulation voltage 50 V AC. Display elements: LED. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN IEC 61326-3-2:2018. Degree of protection: IEC 60529:2001. Protection against electrical shock: UL 61010-1:2012. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BASEEFA 10 ATEX 0061X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInput[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo9.5 VCurrentIo39.22 mAPowerPo93 mW: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I. Voltage: 9.5 V. Current: 39.22 mA. Power: 93 mW. Supply: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Output: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Certificate: BASEEFA 10 ATEX 0062X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012. FM approval: . FM certificateFM 19 CA 0039 X , FM 19 US 0067 XControl drawing116-0457 (cFMus): . FM certificate: FM 19 CA 0039 X , FM 19 US 0067 X. Control drawing: 116-0457 (cFMus). UL approval: E106378. Control drawing116-0332 (cULus): . Control drawing: 116-0332 (cULus). IECEx approval: . IECEx certificateIECEx BAS 10.0024X IECEx BAS 10.0025XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx BAS 10.0024X IECEx BAS 10.0025X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |