KCD2-SLD-Ex1.1065
Solenoid Driver. 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc....
Solenoid Driver. 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC <BR>loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valve. Signal type: Digital Output. Safety Integrity Level (SIL): SIL 3. Systematic capability (SC): SC 3. Connection: terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered. Rated voltage: 19 ... 30 V DC loop powered. Input current: 80 mA at 24 V. Power dissipation: 1.3 W at 24 V. Load: 150 Ω. Connection side: control side. Connection: terminals 5+, 6-. Test pulse length: max. 2 ms from DO card. Signal level: loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited to 5 mA)0-signal: 0 ... 5 V DC. Rated current: 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card). Inrush current: < 200 mA , 10 ms loop powered. Connection side: field side. Connection: terminals 1+, 2-. Internal resistor: 80 Ω. Current: typ. 65 mA. Voltage: typ. 10 V. Current limit: 65 mA. Open loop voltage: typ. 16.4 V. Load: nominal 0.05 ... 18 kΩ , valid range for line fault detection (LFD). Output II: fault signal. Connectionterminals 7, 8 , non-intrinsically safeContact loading30 V DC/ 0.5 A resistive loadMechanical life105 switching cyclesEnergized/De-energized delay≤ 20 ms / ≤ 20 ms: . Connection: terminals 7, 8 , non-intrinsically safe. Contact loading: 30 V DC/ 0.5 A resistive load. Mechanical life: 105 switching cycles. Energized/De-energized delay: ≤ 20 ms / ≤ 20 ms. Line fault detection: . Test currentmax. 350 µA , calculated by ILFD = 4.7 V / (15 kΩ + RLoad): . Test current: max. 350 µA , calculated by ILFD = 4.7 V / (15 kΩ + RLoad). Output/other circuits: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Output II/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff. Display elements: LEDs. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2012 , EN 61326-3-2:2008 For further information see system description.. Degree of protection: IEC 60529:2013. Protection against electrical shock: EN 61010-1:2010. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating.. Degree of protection: IP20. Connection: screw terminals. Mass: approx. 150 g. Dimensions: 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: EXA 17 ATEX 0002 X. Marking II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutput IEx iaVoltageUo17.3 VCurrentIo220 mAPowerPo947 mW: . Marking: II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Output I: Ex ia. Voltage: 17.3 V. Current: 220 mA. Power: 947 mW. Supply: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Input: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Collective error message: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Galvanic isolation: . Output I/other circuitssafe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms: . Output I/other circuits: safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010. UL approval: E106378. Control drawing116-0448 (cULus): . Control drawing: 116-0448 (cULus). IECEx approval: . IECEx certificateIECEx EXA 17.0001XIECEx markingEx nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx EXA 17.0001X. IECEx marking: Ex nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |