PLC⌕
Pepperl Fuchs

KFD2-BR-Ex1.3PA.93

KFD2-BR-Ex1.3PA.93
KFD2-BR-Ex1.3PA.93

Gateway. Segment Coupler 1, intrinsically safe power supply and gateway for coupling PROFIBUS PA devices to PROFIBUS DP, Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PR...

Gateway. Segment Coupler 1, intrinsically safe power supply and gateway for coupling PROFIBUS PA devices to PROFIBUS DP, Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk<BR>Zone 1 - intrinsically safe trunk. Installation in hazardous area: Zone 2 / Div. 2. Connection: Power Rail or terminals 59+, 60-, 58 FE. Rated voltage: 20 ... 35 V DC. Ripple: ≤ 10 %. Rated current: 190 mA ... 430 mA. Number of segments: 1. Rated voltage: 24 ... 26 V. PROFIBUS PA: . Connectionterminals 3, 18+; 2, 17-Rated voltage12.6 ... 13.4 VRated currentmax. 100 mATerminating impedance100 Ω , integrated: . Connection: terminals 3, 18+; 2, 17-. Rated voltage: 12.6 ... 13.4 V. Rated current: max. 100 mA. Terminating impedance: 100 Ω , integrated. PROFIBUS DP: PROFIBUS with RS-485 transmission technology. ConnectionTerminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VPBaud rate93.75 kBit/sTerminating impedancewith rotary switch (S1) switchable: 1 = on; 0 = off: . Connection: Terminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VP. Baud rate: 93.75 kBit/s. Terminating impedance: with rotary switch (S1) switchable: 1 = on; 0 = off. PROFIBUS DP/PROFIBUS PA: safe galvanic isolation acc. to EN 50020, voltage peak value 375 V. PROFIBUS DP/Supply: functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff. PROFIBUS PA/Supply: safe galvanic isolation acc. to EN 50020, voltage peak value 375 V. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Galvanic isolation: EN 50178. Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC 60529. Fieldbus standard: EN 50170/2. Climatic conditions: IEC 60721. Classification: 3K3. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 75 %. Pollution degree: max. 2, according to IEC 60664. Connection type: screw terminal , pluggable. Core cross section: up to 2.5 mm2. Housing: 100 mm x 115 mm x 107 mm. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 650 g. Mounting: DIN rail mounting. EU-type examination certificate: PTB 99 ATEX 2142 , for additional certificates see www.pepperl-fuchs.com. Marking II (1) G [Ex ia] IIC Ga , [exsign] II (1) D [Ex ia] IIIC Da: . Marking: II (1) G [Ex ia] IIC Ga , [exsign] II (1) D [Ex ia] IIIC Da. Supply: . Maximum safe voltageUm253 V AC / 125 V DC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC / 125 V DC (Attention! Um is no rated voltage.). PROFIBUS PA: . VoltageUo15 VCurrentIo207.2 mAPowerPo1.93 WMaximum safe voltageUm60 V: Uo. Voltage: 15 V. Current: 207.2 mA. Power: 1.93 W. Maximum safe voltage: 60 V. Certificate: PF 15 CERT 3527 X. Marking II 3G Ex ec II T4 Gc: . Marking: II 3G Ex ec II T4 Gc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question