PLC⌕
Pepperl Fuchs

KFD2-HLC-Ex1.D

KFD2-HLC-Ex1.D
KFD2-HLC-Ex1.D

HART Loop Converter. 1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 3 analog o...

HART Loop Converter. 1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Rated voltage: 19 ... 30 V DC, Function: transmitter supply, Field device: 3-wire transmitter, Field device [2]: active sources, Signal: HART. Signal type: Analog input. Connection: Power Rail or terminals 23+, 24-. Rated voltage: 19 ... 30 V DC. Rated current: approx. 120 mA at 24 V DC. Power dissipation: 2.3 W. Power consumption: 2.9 W. Conformity: HART field device input (revision 5 to 7). Programming interface: programming socket. Connection side: field side. Connection: terminals 1, 2, 3, 4, 5, 6. Open circuit voltage/short-circuit current: typ. 24 V / 28 mA. Input resistance: 250 Ω , 5 % (terminals 2, 3 and with jumper on 5, 6). Available voltage: ≥ 15.5 V at 20 mA, short-circuit protected. Connection side: control side. Connection: output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21. Output signal: analog. Voltage range: 5 ... 30 V , sink mode from external supply. Current range: 4 ... 20 mA , (source or sink mode). Load: max. 650 Ω , source mode. Fault signal: downscale I ≤ 2 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) or hold measurement value. Other outputs: HART communicator on terminals 22, 24. Collective error message: Power Rail and LED red. Output I, II, III: . Resolutionmax. 2 µAAccuracy< 20 µA, 10 µA typ.Influence of ambient temperature< ± 2 µA/KDuration of measurement/Response delayHART message acquisition time plus 100 ms: . Resolution: max. 2 µA. Accuracy: < 20 µA, 10 µA typ.. Influence of ambient temperature: < ± 2 µA/K. Duration of measurement/Response delay: HART message acquisition time plus 100 ms. Output I/II/III/power supply: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Display elements: LEDs , display. Control elements: Control panel. Configuration: via operating buttons via PACTware. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Low voltage: . Directive 2014/35/EUEN 61010-1:2010: . Directive 2014/35/EU: EN 61010-1:2010. Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Connection: screw terminals. Mass: 300 g. Dimensions: 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BASEEFA 07 ATEX 0174. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC. Supply: . Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V AC (Attention! The rated voltage can be lower.). Equipment: terminals 1, 4/3 (with link between terminals 4 and 5). VoltageUo25.2 VCurrentIo104.9 mAPowerPo0.661 WInternal capacitanceCi1.1 nFInternal inductanceLi0 mH: Uo. Voltage: 25.2 V. Current: 104.9 mA. Power: 0.661 W. Internal capacitance: 1.1 nF. Internal inductance: 0 mH. Equipment: terminals 2, 5/3. VoltageUi< 28 VPowerPi< 1.33 WVoltageUo1.1 VCurrentIo11.9 mAPowerPo4 mWInternal capacitanceCi0 µFInternal inductanceLi0 mH: Ui. Voltage: < 28 V. Power: < 1.33 W. Voltage: 1.1 V. Current: 11.9 mA. Power: 4 mW. Internal capacitance: 0 µF. Internal inductance: 0 mH. Output I, II, III: terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe. Maximum safe voltageUm253 V (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V (Attention! Um is no rated voltage.). Certificate: PF 07 CERT 1142 X. Marking II 3G Ex nA IIC T4 Gc: . Marking: II 3G Ex nA IIC T4 Gc. Galvanic isolation: . Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Other circuits: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . Control drawing116-0129: . Control drawing: 116-0129. IECEx approval: . IECEx certificateIECEx BAS 07.0047IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC: . IECEx certificate: IECEx BAS 07.0047. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question