KFD2-VR4-Ex1.26
Voltage Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2...
Voltage Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Signal: 1 x -20 ... 0 V, Signal: 1 x -20 ... 0 V, Cut-off frequency: 10 kHz (-0,1 dB) <BR>20 kHz (-1 dB). Signal type: Analog input. Safety Integrity Level (SIL): SIL 2. Connection: Power Rail or terminals 11+, 12-. Rated voltage: 19 ... 30 V DC. Ripple: within the supply tolerance. Power dissipation: ≤ 1.2 W. Power consumption: ≤ 1.6 W. Connection side: field side. Connection: terminals 4 (common), 1, 3 and 5 (supply -), 2 and 6 (signal -). Input resistance: 10 kΩ terminals 4 (common), 6-/2-. Output current: terminals 4 (common), 5-: > 10 mA at -21 V or > 20 mA at -18 Vterminals 4 (common), 1-: 5.3 mA ±0.4 mA at -10 Vterminals 4 (common), 3-: 3.6 mA ±0.7 mA at -10 V, 20 °C (68 °F). Transmission range: -20 ... 0 V. Connection side: control side. Connection: terminals 7-, 8+. Voltage: -20 ... 0 V. Load: ≥ 9 kΩ (3-wire sensor), ≥ 2 kΩ (2-wire sensor). Output resistance: 24 Ω typ., 27 Ω maximum Since this is much less than the end-to-end resistance of a zener barrier, it may be necessary to specify a monitor intended for use without a barrier. Please follow the advice of the monitor manufacturer.. Cut-off frequency: 10 kHz (-0,1 dB) 20 kHz (-1 dB). Deviation: DC transfer error (with 10 kΩ load) < 10mV. After calibrationadditional error with AC superimposed is ±5 mV at 20 °C (68 °F) at any point within the span, provided that the alternating component of the input voltage is not excessive, e. g.- square waves (0 ... 20 kHz): 5 Vpp- sine waves (0 ... 20 kHz): the full span of 20 Vpp (= 100 g peak acceleration at 100 mV/g) is acceptable.Influence of ambient temperature(< 100 ppm of span)/K at any point within the span: . After calibration: additional error with AC superimposed is ±5 mV at 20 °C (68 °F) at any point within the span, provided that the alternating component of the input voltage is not excessive, e. g.- square waves (0 ... 20 kHz): 5 Vpp- sine waves (0 ... 20 kHz): the full span of 20 Vpp (= 100 g peak acceleration at 100 mV/g) is acceptable.. Influence of ambient temperature: (< 100 ppm of span)/K at any point within the span. Time delay relative to input: 7.1 ±0.3 µs. Ripple: in 200 kHz bandwidth < 20 mVrmsin 20 kHz bandwidth < 3 mVrms. Output/power supply: functional insulation, rated insulation voltage 50 V AC. Display elements: LED. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN IEC 61326-3-2:2018. Degree of protection: IEC 60529. Protection against electrical shock: UL 61010-1. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 125 g. Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2. Height119 mmWidth20 mmDepth115 mm: . Height: 119 mm. Width: 20 mm. Depth: 115 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BAS 02 ATEX 7206. Marking II (1)G [Ex ia Ga] IIC , [exsign] II (1)D [Ex ia Da] IIICInputEx ia Ga, Ex ia DaVoltageUo-26.4 VCurrentIo90 mAPowerPo570 mW: . Marking: II (1)G [Ex ia Ga] IIC , [exsign] II (1)D [Ex ia Da] IIIC. Input: Ex ia Ga, Ex ia Da. Voltage: -26.4 V. Current: 90 mA. Power: 570 mW. Supply: . Maximum safe voltageUm253 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V (Attention! The rated voltage can be lower.). Output: . Maximum safe voltageUm253 V (Attention! The rated voltage is lower.): Um. Maximum safe voltage: 253 V (Attention! The rated voltage is lower.). EU-type examination certificate: DMT 01 ATEX E 133. Marking I (M1) [Ex ia] I: . Marking: I (M1) [Ex ia] I. Certificate: TÜV 99 ATEX 1499 X. Marking II 3G Ex nA II T4: . Marking: II 3G Ex nA II T4. Galvanic isolation: . Input/Outputsafe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 VInput/power supplysafe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V: . Input/Output: safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V. Input/power supply: safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000. UL approval: . Control drawing116-0316 (cULus): . Control drawing: 116-0316 (cULus). IECEx approval: . IECEx certificateIECEx BAS 05.0078 IECEx BAS 10.0085XIECEx marking[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IEx nA II T4 Gc: . IECEx certificate: IECEx BAS 05.0078 IECEx BAS 10.0085X. IECEx marking: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IEx nA II T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |