PLC⌕
Pepperl Fuchs

NBB15-U1K-E2-3G-3D

NBB15-U1K-E2-3G-3D
NBB15-U1K-E2-3G-3D

Inductive sensor. Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>V...

Inductive sensor. Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>VariKont</i> <sup>®</sup>, Type of voltage: DC, Equipment protection level Gc (ec): IECEx TUR 21.0019X, Equipment protection level Dc (tc): IECEx TUR 21.0020X, Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X, Connection type: screw terminals. Switching function: Normally open (NO). Output type: PNP. Rated operating distance: 15 mm. Installation: flush. Output polarity: DC. Assured operating distance: 0 ... 12.15 mm. Actual operating distance: 13.5 ... 16.5 mm typ. 15 mm. Reduction factor rAl: 0.33. Reduction factor rCu: 0.3. Reduction factor r304: 0.74. Reduction factor rBrass: 0.41. Output type: 3-wire. Operating voltage: 10 ... 30 V. Switching frequency: 0 ... 200 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: pulsing. Voltage drop: ≤ 2 V. Voltage drop at IL: . Voltage drop IL = 1 mA, switching element onUd0.5 ... 2.3 V typ. 0.9 VVoltage drop IL = 10 mA, switching element onUd0.8 ... 2.2 V typ. 1.4 VVoltage drop IL = 20 mA, switching element onUd0.9 ... 2.3 V typ. 1.5 VVoltage drop IL = 50 mA, switching element onUd0.9 ... 2.5 V typ. 1.6 VVoltage drop IL = 100 mA, switching element onUd1 ... 2.6 V typ. 1.8 VVoltage drop IL = 200 mA, switching element onUd1.2 ... 2.8 V typ. 2 V: Ud. Voltage drop IL = 1 mA, switching element on: 0.5 ... 2.3 V typ. 0.9 V. Voltage drop IL = 10 mA, switching element on: 0.8 ... 2.2 V typ. 1.4 V. Voltage drop IL = 20 mA, switching element on: 0.9 ... 2.3 V typ. 1.5 V. Voltage drop IL = 50 mA, switching element on: 0.9 ... 2.5 V typ. 1.6 V. Voltage drop IL = 100 mA, switching element on: 1 ... 2.6 V typ. 1.8 V. Voltage drop IL = 200 mA, switching element on: 1.2 ... 2.8 V typ. 2 V. Operating current: 0 ... 200 mA. Off-state current: 0 ... 0.5 mA typ. 0.01 mA. Off-state current TU =40 °C, switching element off≤ 100 µA: . Off-state current TU =40 °C, switching element off: ≤ 100 µA. No-load supply current: ≤ 20 mA. Time delay before availability: 80 ms. Operating voltage indicator: LED, green. Switching state indicator: LED, yellow. MTTFd: 1242 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level Gc (ec)IECEx TUR 21.0019XEquipment protection level Dc (tc)IECEx TUR 21.0020X: . Equipment protection level Gc (ec): IECEx TUR 21.0019X. Equipment protection level Dc (tc): IECEx TUR 21.0020X. ATEX approval: . Equipment protection level Gc (ec)TÜV 20 ATEX 8525 XEquipment protection level Dc (tc)TÜV 20 ATEX 8526 X: . Equipment protection level Gc (ec): TÜV 20 ATEX 8525 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 200 mA. CCC approval: . Hazardous Location2024322315005962 2024322315005982: . Hazardous Location: 2024322315005962 2024322315005982. Marine approval: DNVGL TAA0000160. Ambient temperature: -25 ... 85 °C (-13 ... 185 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2 , stripped insulation length: 7 mm. Minimum core cross-sectionmin. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors)Maximum core cross-sectionmax. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors): . Minimum core cross-section: min. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors). Maximum core cross-section: max. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors). Connection (system side): screw terminals , M20 x 1.5 cable gland , usable thread length 9.1 mm , screw-in depth max. 9.1 mm. Housing material: PA. Sensing face: PA. Degree of protection: IP68 / IP69K. Mass: 225 g. Dimensions: . Height40 mmWidth40 mmLength118 mm: . Height: 40 mm. Width: 40 mm. Length: 118 mm. Note: Tightening torque: 1.8 Nm (housing). Use in the hazardous area: see instruction manuals

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question