PLC⌕
Pepperl Fuchs

NBB15-U2K-N0

NBB15-U2K-N0
NBB15-U2K-N0

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup>, S...

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>VariKont</i> <sup>®</sup>, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0021X, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Ga: PTB 00 ATEX 2032 X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 15 mm. Installation: flush. Assured operating distance: 0 ... 12.15 mm. Actual operating distance: 13.5 ... 16.5 mm typ. 15 mm. Reduction factor rAl: 0.33. Reduction factor rCu: 0.31. Reduction factor r304: 0.74. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 300 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: yes. Short-circuit protection: yes. Current consumption: . Measuring plate not detectedmin. 2.2 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 2.2 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: LED, yellow. MTTFd: 1660 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Ga: IECEx PTB 11.0021X. Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Da: IECEx PTB 11.0021X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X: . Equipment protection level Ga: PTB 00 ATEX 2032 X. Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Da: PTB 00 ATEX 2032 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0451. CCC approval: . Hazardous Location2020322315002303: . Hazardous Location: 2020322315002303. CML approval: on request. ANZEx: 19.3001X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2. Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2: . Minimum core cross-section: without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2. Maximum core cross-section: without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2. Housing material: PA. Sensing face: PA. Degree of protection: IP68 / IP69K. Mass: 225 g. Dimensions: . Height40 mmWidth40 mmLength118 mm: . Height: 40 mm. Width: 40 mm. Length: 118 mm. Note: Tightening torque: 1.8 Nm (housing). Use in the hazardous area: see instruction manuals

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question