PLC⌕
Pepperl Fuchs

NBB15-U4-Z2

NBB15-U4-Z2
NBB15-U4-Z2

Inductive sensor. Switching function: Normally open/closed (NO/NC), Output type: Two-wire, Installation: flush, Output polarity: DC, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup...

Inductive sensor. Switching function: Normally open/closed (NO/NC), Output type: Two-wire, Installation: flush, Output polarity: DC, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>VariKont</i> <sup>®</sup>, Type of voltage: DC, Connection type: screw terminals, Housing material: PA/metal with epoxy powder coating, Degree of protection: IP68 / IP69K. Switching function: Normally open/closed (NO/NC). Output type: Two-wire. Rated operating distance: 15 mm. Installation: flush. Output polarity: DC. Assured operating distance: 0 ... 12.15 mm. Actual operating distance: 13.5 ... 16.5 mm typ. 15 mm. Reduction factor rAl: 0.3. Reduction factor rCu: 0.3. Reduction factor r304: 0.7. Output type: 2-wire. Operating voltage: 5 ... 60 V. Switching frequency: 0 ... 400 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity tolerant. Short-circuit protection: yes. Voltage drop: ≤ 5 V. Voltage drop at IL: . Voltage drop IL = 100 mA, switching element onUd... 5 V: Ud. Voltage drop IL = 100 mA, switching element on: ... 5 V. Operating current: 2 ... 200 mA. Off-state current: 0 ... 0.5 mA. Switching state indicator: 2 LED, yellow. MTTFd: 1133 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -25 ... 85 °C (-13 ... 185 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2. Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2: . Minimum core cross-section: without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2. Maximum core cross-section: without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2. Housing material: PA/metal with epoxy powder coating. Sensing face: PA. Housing base: metal. Degree of protection: IP68 / IP69K. Mass: 225 g. Dimensions: . Height40 mmWidth40 mmLength118 mm: . Height: 40 mm. Width: 40 mm. Length: 118 mm. Note: Tightening torque: 1.8 Nm (housing)

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question