NBB2-V3-Z4L-3G-3D
Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire with minimum off-state current, Installation: flush, Output polarity: DC, Output type: 2-wire, Construction type: Rectan...
Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire with minimum off-state current, Installation: flush, Output polarity: DC, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 3.7 ... 30 V DC, Type of voltage: DC, Equipment protection level Gc (ec): IECEx TUR 21.0019X, Equipment protection level Dc (tc): IECEx TUR 21.0020X, Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X, Connection type: cable, Housing material: PBT. Switching function: Normally open (NO). Output type: Two-wire with minimum off-state current. Rated operating distance: 2 mm. Installation: flush. Output polarity: DC. Assured operating distance: 0 ... 1.62 mm. Actual operating distance: 1.8 ... 2.2 mm typ.. Reduction factor rAl: 0.25. Reduction factor rCu: 0.2. Reduction factor r304: 0.7. Output type: 2-wire. Operating voltage: 3.7 ... 30 V DC. Switching frequency: 0 ... 700 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: pulsing. Voltage drop: ≤ 3.7 V. Operating current: 2 ... 30 mA. Lowest operating current: 2 mA. Off-state current: ≤ 190 µA. Switching state indicator: LED, yellow. MTTFd: 1879 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level Gc (ec)IECEx TUR 21.0019XEquipment protection level Dc (tc)IECEx TUR 21.0020X: . Equipment protection level Gc (ec): IECEx TUR 21.0019X. Equipment protection level Dc (tc): IECEx TUR 21.0020X. ATEX approval: . Equipment protection level Gc (ec)TÜV 20 ATEX 8525 XEquipment protection level Dc (tc)TÜV 20 ATEX 8526 X: . Equipment protection level Gc (ec): TÜV 20 ATEX 8525 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 30 mA. CCC approval: . Hazardous Location2024322315005978 2024322315005981: . Hazardous Location: 2024322315005978 2024322315005981. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Cable: . Wire end ferrulesyesCable diameter3 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorgreyNumber of cores2Core cross section0.14 mm2LengthL130 mm: . Wire end ferrules: yes. Cable diameter: 3 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Color: grey. Number of cores: 2. Core cross section: 0.14 mm2. Length: 130 mm. Tightening torque, fastening screws: ≤ 0.4 Nm. Dimensions: . Height10.2 mmWidth27.8 mmLength16 mm: . Height: 10.2 mm. Width: 27.8 mm. Length: 16 mm. Use in the hazardous area: see instruction manuals
| Brand | Pepperl Fuchs |
| Lifecycle status | active |