NBN40-L2M-A2-V1-M
Inductive sensor. Extended temperature range, Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: <i>VariKont L</...
Inductive sensor. Extended temperature range, Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: <i>VariKont L</i> <sup>®</sup>, Series: <i>VariKont L</i> <sup>®</sup>, Operating voltage: 10 ... 60 V DC, Type of voltage: DC, Ambient temperature: -40 ... 85 °C (-40 ... 185 °F) <br>, Connection type: Connector plug, Housing material: PA-GF35<BR>metal base powder coated<BR>metal mounting flang powder coated.. Switching function: complementary. Output type: PNP. Rated operating distance: 40 mm. Installation: non-flush. Output polarity: DC. Assured operating distance: 0 ... 32.4 mm. Actual operating distance: 36 ... 44 mm. Reduction factor rAl: 0.34. Reduction factor rCu: 0.3. Reduction factor r304: 0.81. Reduction factor rSt37: 1. Reduction factor rBrass: 0.4. Output type: 4-wire. Operating voltage: 10 ... 60 V DC. Switching frequency: 0 ... 150 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: pulsing. Voltage drop: ≤ 2 V. Operating current: 0 ... 200 mA. Off-state current: 0 ... 0.5 mA. No-load supply current: ≤ 20 mA. Operating voltage indicator: LED, green. Switching state indicator: LED, yellow. MTTFd: 680 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2Fire protectionrequirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26: . Standards: EN IEC 60947-5-2. Fire protection: requirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA. CCC approval: Certified by China Compulsory Certification (CCC). E1 Type approval: 10R-04. Ambient temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: Connector plug. Housing material: PA-GF35metal base powder coatedmetal mounting flang powder coated.. Sensing face: PA-GF35. Degree of protection: IP69K. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Mass: 130 g. Dimensions: . Height40 mmWidth40 mmLength67 mm: . Height: 40 mm. Width: 40 mm. Length: 67 mm
| Brand | Pepperl Fuchs |
| Lifecycle status | active |