PLC⌕
Pepperl Fuchs

NBN40-U4-US-V93

NBN40-U4-US-V93
NBN40-U4-US-V93

Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire, Installation: non-flush, Output polarity: AC/DC, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup>,...

Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire, Installation: non-flush, Output polarity: AC/DC, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>VariKont</i> <sup>®</sup>, Switching frequency: AC, 0 ... 30 Hz<BR>DC, 0 ... 100 Hz, Rated operating voltage: 24 ... 250 V DC / 24 ... 230 V AC, Operating voltage: 20 ... 300 V DC / 20 ... 253 V AC, Connection type: Connector plug, Housing material: PA 6.6 / metal, Degree of protection: IP67. Switching function: Normally open (NO). Output type: Two-wire. Rated operating distance: 40 mm. Installation: non-flush. Output polarity: AC/DC. Assured operating distance: 0 ... 32.4 mm. Actual operating distance: 36 ... 44 mm typ. 40 mm. Reduction factor rAl: 0.37. Reduction factor rCu: 0.3. Reduction factor r304: 0.73. Reduction factor rFe: 1. Reduction factor rBrass: 0.4. Output type: 2-wire. Switching frequency: AC, 0 ... 30 HzDC, 0 ... 100 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity tolerant. Short-circuit protection: pulsing. Voltage drop: ≤ 5 V (typ. 2V) DC operation ≤ 8 V (typ. 2V) AC operation. Momentary current(20 ms, 0.1 Hz): 0 ... 3000 mA. Operating current: 5 ... 500 mA. Off-state current: ≤ 1.5 mA. Time delay before availability: ≤ 300 ms. Operating voltage indicator: LED, green. Switching state indicator: LED, yellow. Error indicator: flashes when overcurrent. MTTFd: 540 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Rated operating voltage: 24 ... 250 V DC / 24 ... 230 V AC. Operating voltage: 20 ... 300 V DC / 20 ... 253 V AC. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. Protection class: I. Rated insulation voltageUi230 VRated impulse withstand voltageUimp2.5 kV: Ui. Rated insulation voltage: 230 V. Rated impulse withstand voltage: 2.5 kV. UL approval: cULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1 Supply/Switching Voltage: 250 V AC / 273 V DC Output Switching Current: 500 mA Further UL information see section "Additional Information". Ambient temperature: -25 ... 85 °C (-13 ... 185 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Connection type: Connector plug. Housing material: PA 6.6 / metal. Sensing face: PA 6.6. Housing base: metal / class I equipment with ground connection. Degree of protection: IP67. Connector: . Threading7/8 inch-16 UNNumber of pins3: . Threading: 7/8 inch-16 UN. Number of pins: 3. Mass: 320 g. Dimensions: . Height40 mmWidth40 mmLength118 mm: . Height: 40 mm. Width: 40 mm. Length: 118 mm

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question