PLC⌕
Pepperl Fuchs

NCB10-30GM40-N0-5M-OG

NCB10-30GM40-N0-5M-OG
NCB10-30GM40-N0-5M-OG

Inductive sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 3-wire, Thread mold: M30, Con...

Inductive sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 10 mm. Installation: flush. Assured operating distance: 0 ... 8.1 mm. Actual operating distance: 9 ... 11 mm typ.. Reduction factor rAl: 0.32. Reduction factor rCu: 0.32. Reduction factor r304: 0.72. Output type: 3-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 650 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Suitable for 2:1 technology: yes , Reverse polarity protection diode not required. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: LED, yellow. MTTFd: 1870 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X: . Equipment protection level Ga: IECEx PTB 11.0037X. Equipment protection level Gb: IECEx PTB 11.0037X. Equipment protection level Da: IECEx PTB 11.0037X. Equipment protection level Mb: IECEx PTB 11.0037X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X: . Equipment protection level Ga: PTB 00 ATEX 2048 X. Equipment protection level Gb: PTB 00 ATEX 2048 X. Equipment protection level Da: PTB 00 ATEX 2048 X. UL approval: cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0452. ANZEx: 18.3018X. Ambient temperature: -25 ... 80 °C (-13 ... 176 °F). Storage temperature: -40 ... 80 °C (-40 ... 176 °F). Connection type: cable. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP66 / IP67. Cable: . Wire end ferrulesyesCable diameter6.7 mm ± 0.3 mmBending radius> 7.5 x cable diameterMaterialPURColorblueNumber of cores2Core cross section0.5 mm2LengthL5 m: . Wire end ferrules: yes. Cable diameter: 6.7 mm ± 0.3 mm. Bending radius: > 7.5 x cable diameter. Material: PUR. Color: blue. Number of cores: 2. Core cross section: 0.5 mm2. Length: 5 m. Dimensions: . Length40 mmDiameter30 mm: . Length: 40 mm. Diameter: 30 mm. Note: The shield is not connected to the sensor.. Scope of delivery: 2 self locking nuts in scope of delivery. Use in the hazardous area: see instruction manuals

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question