PLC⌕
Pepperl Fuchs

NCN40-L2-N0-V1

NCN40-L2-N0-V1
NCN40-L2-N0-V1

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Construction type: <i>VariKont L</i> <sup>®</sup>, Series: <i>VariK...

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Construction type: <i>VariKont L</i> <sup>®</sup>, Series: <i>VariKont L</i> <sup>®</sup>, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0021X, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Dc (tc): IECEx TUR 21.0020X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 40 mm. Installation: non-flush. Assured operating distance: 0 ... 32.4 mm. Actual operating distance: 36 ... 44 mm. Reduction factor rAl: 0.31. Reduction factor rCu: 0.3. Reduction factor r304: 0.74. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 150 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Current consumption: . Measuring plate not detected≥ 2.2 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 2.2 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: LED, yellow. Safety Integrity Level (SIL): SIL 2. MTTFd: 1670 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level Dc (tc)IECEx TUR 21.0020XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Ga: IECEx PTB 11.0021X. Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Da: IECEx PTB 11.0021X. Equipment protection level Dc (tc): IECEx TUR 21.0020X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 XEquipment protection level Dc (tc)TÜV 20 ATEX 8526 X: . Equipment protection level Ga: PTB 00 ATEX 2032 X. Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Da: PTB 00 ATEX 2032 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X. Protection class: II. Rated insulation voltageUi253 VRated impulse withstand voltageUimp4000 V: Ui. Rated insulation voltage: 253 V. Rated impulse withstand voltage: 4000 V. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0451. CCC approval: . Hazardous Location2020322315002302 2024322315005982: . Hazardous Location: 2020322315002302 2024322315005982. CML approval: on request. ANZEx: 19.3001X. Marine approval: DNVGL TAA00001A5. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: Connector plug. Housing material: PA. Sensing face: PA. Degree of protection: IP69K. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Mass: 130 g. Dimensions: . Height40 mmWidth40 mmLength67 mm: . Height: 40 mm. Width: 40 mm. Length: 67 mm. Use in the hazardous area: see instruction manuals

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question