NCN50-FP-A2-P1-3G-3D
Inductive sensor. Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: Rectangular, Series: Rectangular type, Oper...
Inductive sensor. Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 60 V DC, Type of voltage: DC, Equipment protection level Gc (ec): IECEx TUR 21.0019X, Equipment protection level Dc (tc): IECEx TUR 21.0020X, Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X, Connection type: screw terminals. Switching function: complementary. Output type: PNP. Rated operating distance: 50 mm. Installation: non-flush. Output polarity: DC. Assured operating distance: 0 ... 40.5 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 4-wire. Operating voltage: 10 ... 60 V DC. Switching frequency: 0 ... 80 Hz. Hysteresis: typ. 3 %. Reverse polarity protection: reverse polarity protected. Voltage drop: ≤ 3 V. Operating current: 0 ... 200 mA. Off-state current: 0 ... 0.5 mA. No-load supply current: ≤ 20 mA. Time delay before availability: ≤ 300 ms. Operating voltage indicator: LED, green. Switching state indicator: LED, yellow. MTTFd: 671 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level Gc (ec)IECEx TUR 21.0019XEquipment protection level Dc (tc)IECEx TUR 21.0020X: . Equipment protection level Gc (ec): IECEx TUR 21.0019X. Equipment protection level Dc (tc): IECEx TUR 21.0020X. ATEX approval: . Equipment protection level Gc (ec)TÜV 20 ATEX 8525 XEquipment protection level Dc (tc)TÜV 20 ATEX 8526 X: . Equipment protection level Gc (ec): TÜV 20 ATEX 8525 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8526 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA. CCC approval: . Hazardous Location2024322315005962 2024322315005982: . Hazardous Location: 2024322315005962 2024322315005982. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2 , stripped insulation length: 7 mm. Minimum core cross-sectionmin. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors)Maximum core cross-sectionmax. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors): . Minimum core cross-section: min. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors). Maximum core cross-section: max. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors). Connection (system side): screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm. Housing material: PBT. Sensing face: PBT. Housing base: PBT. Degree of protection: IP67. Mass: 440 g. Tightening torque, housing screws: 1 Nm. Dimensions: . Height40 mmWidth80 mmLength80 mm: . Height: 40 mm. Width: 80 mm. Length: 80 mm. Use in the hazardous area: see instruction manuals
| Brand | Pepperl Fuchs |
| Lifecycle status | active |