PLC⌕
Pepperl Fuchs

NJ1,5-8GM-N-V1

NJ1,5-8GM-N-V1
NJ1,5-8GM-N-V1

Inductive sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M8, Cons...

Inductive sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M8, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 1.5 mm. Installation: flush. Assured operating distance: 0 ... 1.215 mm. Actual operating distance: 1.35 ... 1.65 mm typ.. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 5000 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Suitable for 2:1 technology: yes , Reverse polarity protection diode not required. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 2. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X: . Equipment protection level Gb: IECEx PTB 11.0037X. Equipment protection level Da: IECEx PTB 11.0037X. Equipment protection level Mb: IECEx PTB 11.0037X. ATEX approval: . Equipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X: . Equipment protection level Gb: PTB 00 ATEX 2048 X. Equipment protection level Da: PTB 00 ATEX 2048 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. CCC approval: . Hazardous Location2020322315002256: . Hazardous Location: 2020322315002256. CML approval: on request. ANZEx: 18.3018X. Marine approval: DNVGL TAA00001A5. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Connection type: Connector plug. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Dimensions: . Length43 mmDiameter8 mm: . Length: 43 mm. Diameter: 8 mm. Scope of delivery: 2 self locking nuts in scope of delivery. Use in the hazardous area: see instruction manuals

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question