NJ2-V3-N-Y211641
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangula...
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Gb: PTB 00 ATEX 2032 X, Equipment protection level Da: PTB 00 ATEX 2032 X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 2 mm. Installation: flush. Assured operating distance: 0 ... 1.62 mm. Reduction factor rAl: 0.25. Reduction factor rCu: 0.2. Reduction factor r304: 0.7. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 1000 Hz. Hysteresis: typ. %. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 2. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Da: IECEx PTB 11.0021X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X: . Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Da: PTB 00 ATEX 2032 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. CML approval: on request. ANZEx: 19.3001X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Cable: . Bending radius> 10 x cable diameterMaterialPVCCore cross section0.14 mm2LengthL2 m: . Bending radius: > 10 x cable diameter. Material: PVC. Core cross section: 0.14 mm2. Length: 2 m. Tightening torque, fastening screws: ≤ 0.4 Nm. Dimensions: . Height10.2 mmWidth27.8 mmLength16 mm: . Height: 10.2 mm. Width: 27.8 mm. Length: 16 mm. Use in the hazardous area: see instruction manuals
| Brand | Pepperl Fuchs |
| Lifecycle status | active |