NJ40-FP-SN-P1
Inductive sensor. Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: non-flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular t...
Inductive sensor. Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: non-flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X, Equipment protection level Gb: PTB 00 ATEX 2049 X, Equipment protection level Da: PTB 00 ATEX 2049 X. Switching function: Normally closed (NC). Output type: NAMUR with safety function. Rated operating distance: 40 mm. Installation: non-flush. Assured operating distance: 0 ... 32.4 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Safety Integrity Level (SIL): up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 100 Hz. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 3. MTTFd: 7560 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GbIECEx PTB 11.0092XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GbPTB 00 ATEX 2049 XEquipment protection level DaPTB 00 ATEX 2049 X: . Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Da: PTB 00 ATEX 2049 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. CCC approval: . Hazardous Location2020322315002308: . Hazardous Location: 2020322315002308. KCC approval: . Hazardous Location18-AV4BO-0478X: . Hazardous Location: 18-AV4BO-0478X. Ambient temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: screw terminals. Core cross section: up to 2.5 mm2 , stripped insulation length: 7 mm. Connection (system side): screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm. Housing material: PBT. Sensing face: PBT. Degree of protection: IP68. Dimensions: . Height40 mmWidth80 mmLength80 mm: . Height: 40 mm. Width: 80 mm. Length: 80 mm. Use in the hazardous area: see instruction manuals
| Brand | Pepperl Fuchs |
| Lifecycle status | active |