PLC⌕
Pepperl Fuchs

NJ40+U1+E2

NJ40+U1+E2
NJ40+U1+E2

Inductive sensor. Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series:...

Inductive sensor. Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>VariKont</i> <sup>®</sup>, Type of voltage: DC, Connection type: screw terminals, Housing material: PBT, Degree of protection: IP68. Switching function: Normally open (NO). Output type: PNP. Rated operating distance: 40 mm. Installation: non-flush. Output polarity: DC. Assured operating distance: 0 ... 32.4 mm. Actual operating distance: 36 ... 44 mm typ. 40 mm. Reduction factor rAl: 0.5. Reduction factor rCu: 0.45. Reduction factor r304: 0.8. Output type: 3-wire. Operating voltage: 10 ... 60 V. Switching frequency: 0 ... 100 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: pulsing. Voltage drop: ≤ 2.8 V. Voltage drop at IL: . Voltage drop IL = 1 mA, switching element onUd0.5 ... 2.3 V typ. 0.9 VVoltage drop IL = 10 mA, switching element onUd0.8 ... 2.2 V typ. 1.4 VVoltage drop IL = 20 mA, switching element onUd0.9 ... 2.3 V typ. 1.5 VVoltage drop IL = 50 mA, switching element onUd0.9 ... 2.5 V typ. 1.6 VVoltage drop IL = 100 mA, switching element onUd1 ... 2.6 V typ. 1.8 VVoltage drop IL = 200 mA, switching element onUd1.2 ... 2.8 V typ. 2 V: Ud. Voltage drop IL = 1 mA, switching element on: 0.5 ... 2.3 V typ. 0.9 V. Voltage drop IL = 10 mA, switching element on: 0.8 ... 2.2 V typ. 1.4 V. Voltage drop IL = 20 mA, switching element on: 0.9 ... 2.3 V typ. 1.5 V. Voltage drop IL = 50 mA, switching element on: 0.9 ... 2.5 V typ. 1.6 V. Voltage drop IL = 100 mA, switching element on: 1 ... 2.6 V typ. 1.8 V. Voltage drop IL = 200 mA, switching element on: 1.2 ... 2.8 V typ. 2 V. Operating current: 0 ... 200 mA. Off-state current: 0 ... 0.5 mA typ. 0.01 mA. Off-state current TU =40 °C, switching element off≤ 100 µA: . Off-state current TU =40 °C, switching element off: ≤ 100 µA. No-load supply current: ≤ 10 mA. Time delay before availability: ≤ 100 ms. Operating voltage indicator: LED, green. Switching state indicator: LED, yellow. MTTFd: 580 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2. Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2: . Minimum core cross-section: without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2. Maximum core cross-section: without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2. Housing material: PBT. Sensing face: PBT. Degree of protection: IP68. Dimensions: . Height55 mmWidth55 mmLength128 mm: . Height: 55 mm. Width: 55 mm. Length: 128 mm

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question