RD0-TI-Ex8.FF.*

RD0-TI-Ex8.FF.*
RD0-TI-Ex8.FF.*

Temperature Multi-Input. Temperature multi-input, electronic component for control cabinet installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors...

Temperature Multi-Input. Temperature multi-input, electronic component for control cabinet installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada. Design / Mounting: Cabinet installation. Installation in hazardous area: Zone 1 / Div. 1. Fieldbus type: FOUNDATION Fieldbus. Physical layer profile: profile type 511 (FISCO), profile type 111 (Entity). ITK version: 6.2.0 (DEV_REV 02). Implementation: resource block 1x RSfunction block 8x AI, 1x MAItransducer block 8x sensor TB, 1x concentrator TB. Execution time: AI, MAI 40 ms max.. Macro cycle: typical for one device 8xAI or 1xMAI max. 500 ms. Firmware update: via separate plug connection. FDE (Fault Disconnect Equipment): 6.7 mA. Polarity: not polarity sensitive. Rated voltage: 9 ... 32 V. Rated current: max. 23 mA. LED PWR: green: on, bus voltage existent. LED COM ERR: red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error. LED CHANNEL ERROR: red: 2 Hz flashing: lead breakage, overrange; off: no error. Number: 8. Sensor types: see table 1. Grounding: grounding of thermoelements possible. Error detection: lead breakage, wiring error, hardware device error. Common mode voltage: Input to Input 600 Vpeak. Deviation: . Cold junction compensation± 0.5 °C (32.9 °F)Resolution/accuracysee table 2Influence of ambient temperaturesee table 3LinearizationT/C input 0.1°C RTD input 0.03°C: . Cold junction compensation: ± 0.5 °C (32.9 °F). Resolution/accuracy: see table 2. Influence of ambient temperature: see table 3. Linearization: T/C input 0.1°C RTD input 0.03°C. Internal measurement cycle: for all sensor types max. 1 s. Fieldbus/inputs: safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Galvanic isolation: EN 60079-11. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F) hazardous area -40 ... 85 °C (-40 ... 185 °F) safe area. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: ≤ 95 % non-condensing. Shock resistance: 15 g , 11 ms. Vibration resistance: 5 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: plug-in terminals , spring terminal and screw terminal. Core cross section: . Busup to 2.5 mm2Inputsup to 2.5 mm2: . Bus: up to 2.5 mm2. Inputs: up to 2.5 mm2. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 360 g. Mounting: DIN rail mounting. EU-type examination certificate: PTB 03 ATEX 2237. Marking II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc: . Marking: II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc. Bus: FISCO see EC-Type Examination Certificate. Inputs: see EC-Type Examination Certificate. Certificate: PTB 03 ATEX 2238 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Galvanic isolation: . Bussee Statement of ConformityInputsee EC-Type Examination Certificate: . Bus: see Statement of Conformity. Input: see EC-Type Examination Certificate. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . FM certificateFM18US0054X , FM18CA0027XControl drawing16-473FM-12A: . FM certificate: FM18US0054X , FM18CA0027X. Control drawing: 16-473FM-12A. IECEx approval: . IECEx certificateIECEx PTB 05.0001 IECEx PTB 05.0002XIECEx markingEx ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc: . IECEx certificate: IECEx PTB 05.0001 IECEx PTB 05.0002X. IECEx marking: Ex ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question