PLC⌕
Pepperl Fuchs

SJ3,5-SN

SJ3,5-SN
SJ3,5-SN

Inductive slot sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction typ...

Inductive slot sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X. Switching function: Normally closed (NC). Output type: NAMUR with safety function. Slot width: 3.5 mm. Depth of immersion (lateral): 5 ... 7 typ. 6 mm. Reference target: 10 x 7 x 0.3 mm3, Al. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 3000 Hz. Hysteresis: with NAMUR switch amplifier: 0.045 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.025 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1). Suitable for 2:1 technology: yes , with reverse polarity protection diode. Rate of current rise: -4.5 mA / mm. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected0.2 ... 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: 0.2 ... 1 mA. Safety Integrity Level (SIL): SIL 3. MTTFd: 11800 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Ga: IECEx PTB 11.0092X. Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level DaPTB 00 ATEX 2049 X: . Equipment protection level Ga: PTB 00 ATEX 2049 X. Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Da: PTB 00 ATEX 2049 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0454. CCC approval: . Hazardous Location2020322315002308: . Hazardous Location: 2020322315002308. NEPSI approval: . NEPSI certificateGYJ16.1392X: . NEPSI certificate: GYJ16.1392X. Ambient temperature: -50 ... 100 °C (-58 ... 212 °F) Safety application: -40 ... 100°C. Connection type: flexible leads LiY. Housing material: PBT. Degree of protection: IP67. Cable: . Cable diameter1.1 mm ± 0.1 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.14 mm2LengthL500 mm: . Cable diameter: 1.1 mm ± 0.1 mm. Bending radius: > 10 x cable diameter. Material: PVC. Core cross section: 0.14 mm2. Length: 500 mm. Dimensions: . Height15 mmWidth10 mmLength19.5 mm: . Height: 15 mm. Width: 10 mm. Length: 19.5 mm. Note: adjustable stop Security relevant only up to -40°C. Use in the hazardous area: see instruction manuals

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question