PLC⌕
Pepperl Fuchs

SR.CS2*

SR.CS2*
SR.CS2*

Control Stations Division 2, Stainless Steel. For use in North America, Stainless Steel enclosure, Certified for Class I, Division 2 hazardous areas, Up to 107 operators per control station, 10 enclos...

Control Stations Division 2, Stainless Steel. For use in North America, Stainless Steel enclosure, Certified for Class I, Division 2 hazardous areas, Up to 107 operators per control station, 10 enclosure size options, Return Flange Sealing provides Drain Channel, Customizable configuration of operators, cable entry quantities and cable gland types as per specification, Customizable configuration of gland plates, ground bolt and hinges as per specification, Option for vertical or horizontal mounting provides high flexibility, Up to 4 gland plates. Operating voltage: 250 V AC max.. Operating current: 5 A max.. Terminal capacity: 2.5 mm2. Terminal torque0.8 Nm ... 1.2 Nm: . Terminal torque: 0.8 Nm ... 1.2 Nm. Enclosure cover: fully detachable , hinged. Cover fixing: Stainless steel A4 (V4A) combination pozi driv and slotted screw , optional quarter-turn key locks. Cover seal: silicone. Degree of protection: Type 4X. Cable entry: cable glands as per specification. Gland plate on face(s)optional: . Gland plate on face(s): optional. Material: . Enclosure1.5 mm AISI 316L, (1.4404) stainless steelGland plateoptional 3 mm or 6 mm AISI 316L (1.4404) stainless steelFinishbrushed: . Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steel. Gland plate: optional 3 mm or 6 mm AISI 316L (1.4404) stainless steel. Finish: brushed. Mass: see data table valid for empty enclosure, will increase according to integrated components. Dimensions: see data table. Mounting: screws , optional mounting brackets enclosed. Grounding: M6 internal/external brass nickel-plated grounding bolt M6 internal stainless steel grounding bolt welded to lid M6 internal stainless steel grounding bolt welded to enclosure body. Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) depending on integrated components. ETL approval: . ETL certificateIntertek 5003368 , Intertek 5022079Approved forClass I, Division 2, Groups A, B, C, DcETLusaccording to UL 508A , UL 121201 , CSA C22.2, No. 213, 286Ambient temperature-25 ... 40 °C (-13 ... 104 °F) T6 -40 ... 55 °C (-40 ... 131 °F) T5: . ETL certificate: Intertek 5003368 , Intertek 5022079. Approved for: Class I, Division 2, Groups A, B, C, D. cETLus: according to UL 508A , UL 121201 , CSA C22.2, No. 213, 286. Ambient temperature: -25 ... 40 °C (-13 ... 104 °F) T6 -40 ... 55 °C (-40 ... 131 °F) T5. Degree of protection: UL 50 / UL 50E. Ordering information: This device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.. Optional accessories: Mounting plate M6 internal/external stainless steel grounding bolt gland plate 3 mm AISI 316L (1.4404) stainless steelgland plate 6 mm AISI 316L (1.4404) stainless steel M6 internal stainless steel grounding bolt welded to bottom gland plate quarter-turn key locks stainless steel A4 (V4A) engraved traffolyte tag labelengraved AISI 316L stainless steel tag labelcolor in-fill stainless steel tag label cover padlock facility. Control elements: small footprint max. 107 see data table all NC contacts have a direct opening action for emergency stop functions

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question