TPH-LBF-IA1.36.DE*
Surge Protector. Surge protector, pluggable module for trunk installation on fieldbus power hub, Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fi...
Surge Protector. Surge protector, pluggable module for trunk installation on fieldbus power hub, Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada. Design / Mounting: Cabinet installation. Installation in hazardous area: Zone 1 / Div. 1. Self current consumption: max. 6 mA (for version TPH-LBF-IA1.36.DE.1) , max. 0 mA (for version TPH-LBF-IA1.36.DE.0). LED ERR: green flashing: status OK , red flashing: maintenance required , (for version TPH-LBF-IA1.36.DE.1). Rated voltage: 36 V. Rated current: 600 mA. Voltage protection level: . Line/Linemax. 50 V category B2 10/700 µsec , 25 A max. 52 V category C1 8/20 µsec , 300 A max. 55 V category C2 8/20 µsec , 5 kA max. 46 V category C3 1 kV/µsec , 10 A Line/Earthmax. 1060 V category B2 10/700 µsec , 50 A per linemax. 800 V category C1 8/20 µsec , 300 A per linemax. 1450 V category C2 8/20 µsec , 5 kA per linemax. 1300 V category C3 1 kV/µsec , 50 A per linemax. 1080 V category D1 10/350 µsec , 500 A per line: . Line/Line: max. 50 V category B2 10/700 µsec , 25 A max. 52 V category C1 8/20 µsec , 300 A max. 55 V category C2 8/20 µsec , 5 kA max. 46 V category C3 1 kV/µsec , 10 A. Line/Earth: max. 1060 V category B2 10/700 µsec , 50 A per linemax. 800 V category C1 8/20 µsec , 300 A per linemax. 1450 V category C2 8/20 µsec , 5 kA per linemax. 1300 V category C3 1 kV/µsec , 50 A per linemax. 1080 V category D1 10/350 µsec , 500 A per line. Reaction time: . Line/Linemax. 1 nsLine/Earthmax. 100 ns: . Line/Line: max. 1 ns. Line/Earth: max. 100 ns. Overstressed fault mode: according IEC 61643-21 line inoperable mode 3. Series resistance in line: 2 Ω +/- 5 %. Impulse durability: . Per line5 kA category C2 8/20 µsec: . Per line: 5 kA category C2 8/20 µsec. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NAMUR NE 21. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Climatic conditions: IEC 60721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Surge protection: IEC 61643-21. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: ≤ 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: screw terminals. Core cross section: flexible wire 2.5 mm2 solid wire max. 4 mm2. Housing material: Polyamide PA 6.6. Degree of protection: IP20. Mass: 45 g. Grounding: M4 screw and external grounding rail. EU-type examination certificate: SIRA 12 ATEX 2128X. Marking II 1G Ex ia IIC T4VoltageUi24 VCurrentIi500 mAInternal capacitanceCi2 nFInternal inductanceLi 0.1 µH: . Marking: II 1G Ex ia IIC T4. Voltage: 24 V. Current: 500 mA. Internal capacitance: 2 nF. Internal inductance: 0.1 µH. Certificate: SIRA 12 ATEX 4176X. Marking II 3G Ex nAc IIC T4 , [exsign] II 3G Ex ic IIC T4 Class I and II, Division 1, Group C - GVoltageUi33 VCurrentIi600 mAInternal capacitanceCi2 nF: . Marking: II 3G Ex nAc IIC T4 , [exsign] II 3G Ex ic IIC T4 Class I and II, Division 1, Group C - G. Voltage: 33 V. Current: 600 mA. Internal capacitance: 2 nF. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007. Supplementary information: FISCO field device. CSA approval: CoC 2595441. Control drawing116-0365Approved forClass I, Division 1, Groups A, B, C, D T4Class I, Zone 1, Ex ia IIC T4Class I, Zone 2, Ex ic IIC T4Class I, Zone 0, AEx ia IIC T4Class I, Zone 2, AEx ic IIC T4Class I, Division 2, Groups A, B, C, D T4Class I, Zone 2, Ex nL IIC T4Class I, Zone 2, Ex na IIC T4Class I, Zone 2, AEx nAc IIC T4: . Control drawing: 116-0365. Approved for: Class I, Division 1, Groups A, B, C, D T4Class I, Zone 1, Ex ia IIC T4Class I, Zone 2, Ex ic IIC T4Class I, Zone 0, AEx ia IIC T4Class I, Zone 2, AEx ic IIC T4Class I, Division 2, Groups A, B, C, D T4Class I, Zone 2, Ex nL IIC T4Class I, Zone 2, Ex na IIC T4Class I, Zone 2, AEx nAc IIC T4. IECEx approval: IECEx SIR 12.0051X. Approved forEx ia IIC T4: . Approved for: Ex ia IIC T4. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
| Brand | Pepperl Fuchs |
| Lifecycle status | active |