PLC⌕
Pepperl Fuchs

VAA-4E-G4-ZE

VAA-4E-G4-ZE
VAA-4E-G4-ZE

AS-Interface sensor module. G4 module IP67, 4 inputs (PNP). Node type: Standard node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.0. UL File Number: E223772. LED PWR/FAULT:...

AS-Interface sensor module. G4 module IP67, 4 inputs (PNP). Node type: Standard node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.0. UL File Number: E223772. LED PWR/FAULT: dual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply. LED IN: switching state (input); 4 LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 40 mA (without sensors) / max. 190 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 ... 31 V. Current loading capacity: ≤ 150 mA (TB ≤ 40 °C),≤ 120 mA (TB ≤ 60 °C), short-circuit protected. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005. Profile: S-0.0. IO code: 0. ID code: 0. ID1 code: F. ID2 code: E. Data bits (function via AS-Interface): InputOutput. D0 IN1 -D1 IN2 -D2 IN3 -D3 IN4 -: . D0: IN1 -. D1: IN2 -. D2: IN3 -. D3: IN4 -. Parameter bits (programmable via AS-i): function. P0not usedP1not usedP2not usedP3not used: . P0: not used. P1: not used. P2: not used. P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 3. Degree of protection: IP67. Connection: cable piercing method or terminal compartmentyellow flat cable or standard round cableinputs: M12 x 1.5 cable gland and cage tension spring terminals. Material: . HousingPA 6 GF30: . Housing: PA 6 GF30. Mass: 180 g. Tightening torque, housing screws: 0.8 Nm. Dimensions: . Height51 mmWidth45 mmLength102 mm: . Height: 51 mm. Width: 45 mm. Length: 102 mm. Mounting: DIN rail or screw mounting

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question