VAA-4E4A-KE-ZE/R
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs (PNP) and 4 relay outputs. Node type: Standard node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.0. P...
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs (PNP) and 4 relay outputs. Node type: Standard node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.0. Profile: S-7.0. IO code7ID code0ID1 codeFID2 codeE: . IO code: 7. ID code: 0. ID1 code: F. ID2 code: E. UL File Number: E106378. LED FAULT: Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Auxiliary voltage (input): 12 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (no sensors)/max. 210 mA. Surge protection: O1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT). Voltage: 21 ... 31 V DC (INT). Current loading capacity: ≤ 150 mA, overload- and short-circuit protected (INT). Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Signal delay: < 2 ms (input/AS-Interface). Number/Type: 4 relay outputs, normally open. Supply: none. Nominal load: . Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V ACPer module8 A: . Per contact: 2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC. Per module: 8 A. Control circuit: ≤ 8 mA per relay (from AS-Interface). Switching delay: < 10 ms (AS-Interface/contact). Usage category: DC-13 and AC-14. Switching: . Mechanical5 x 106Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4): . Mechanical: 5 x 106. Electrical: 0.2 x 106 (250 V AC, 2 A, cos φ = 0.4). Input/Output: safe isolation, rated insulation voltage 300 V AC. Input/AS-Interface: Switch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC. Output/Output: basic insulation, rated insulation voltage 300 V AC. Output/AS-Interface: safe isolation, rated insulation voltage 300 V AC. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61326:2003: . Directive 2014/30/EU: EN 62026-2:2013 EN 61326:2003. Low voltage: . Directive 73/23/EECEN 60947-1:2007: . Directive 73/23/EEC: EN 60947-1:2007. Galvanic isolation: EN 60664-1:2007. Electromagnetic compatibility: NAMUR NE 21: 1998-08. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. AS-Interface: EN 62026-2:2013. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 170 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm ... 0.6 Nm
| Brand | Pepperl Fuchs |
| Lifecycle status | active |