PLC⌕
Pepperl Fuchs

VAN-115/230AC-K27

VAN-115/230AC-K27
VAN-115/230AC-K27

AS-Interface power supply. AS-Interface power supply, data decoupling, 4 A. UL File Number: E223176. MTBF: 100 a. Reset push-button switch: earth fault simulation/reset of earth fault display. LED EFD...

AS-Interface power supply. AS-Interface power supply, data decoupling, 4 A. UL File Number: E223176. MTBF: 100 a. Reset push-button switch: earth fault simulation/reset of earth fault display. LED EFD: earth fault display; LED red. LED AS-i ok: LED green:ON: AS-Interface voltage OKOFF: overload or no supply voltage. Fusing: T3A 15/250 V HBC (not accessible). Rated operating voltage: 85 … 132 VAC184 … 264 VAC 240 … 300 VDC. Rated operating current: 2.7 A at 115 VAC1.3 A at 230 VAC. Supply frequency: 47 ... 63 Hz (alternatively, DC possible). Efficiency: typ. 90 % (230 VAC, 4 A). Galvanic isolation: SELV/PELV. Peak inrush current: < 3.7 A2s (120 VAC)< 4.6 A2s (132 VAC)< 2.5 A2s (230 VAC)< 3.3 A2s (264 VAC). Short-circuit protection/overload: > 4,2 A< 6.5 A. Current limit: starts at > 4.2 A. Voltage: 30.5 VDC ±3 % fixed setting. Current: 4 A. Residual ripple: < 50 mVSS (500 kHz bandwidth, 50 Ω measurement, with resistive load). Voltage limitation: limited to max. 55 V. Directive conformity: . EMC Directive 2004/108/ECEN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001: . EMC Directive 2004/108/EC: EN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001. Standard conformity: . Noise immunityEN 61000-6-2:2005Emitted interferenceEN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009Galvanic isolationIEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV)Degree of protectionIEC 60529:2001Pollution degreeEN 50178:1997Mech. capacityEN 60068-2-6:2008 (Sinus) EN 60068-2-64:2009 (Random)Shock and impact resistanceEN 60068-2-27:1995: . Noise immunity: EN 61000-6-2:2005. Emitted interference: EN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009. Galvanic isolation: IEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV). Degree of protection: IEC 60529:2001. Pollution degree: EN 50178:1997. Mech. capacity: EN 60068-2-6:2008 (Sinus) EN 60068-2-64:2009 (Random). Shock and impact resistance: EN 60068-2-27:1995. Ambient temperature: -10 ... 70 °C (14 ... 158 °F) note derating. Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Shock and impact resistance: 15g/6 ms10g/11 ms. Vibration resistance: Sine 2 - 17.8 Hz: ± 1.6 mm Sine 17.8 ... 500 Hz : 2 g Random 2 … 500 Hz: 0.5 m2 (s³). Pollution degree: 2. Degree of protection: IP20. Protection class: 1 (IEC 60536); Protective conductor connection necessary. Connection: Connection terminals, max. conductor cross-section Flexible cable: 0.5 … 4 mm2Rigid cable: 0.5 … 6 mm2Stripping length 7 mm. Mass: 650 g. Dimensions: . Height124 mmWidth73 mmLength102 mm: . Height: 124 mm. Width: 73 mm. Length: 102 mm. Mounting: DIN mounting rail

BrandPepperl Fuchs
Lifecycle statusactive

Not currently in stock

Price on request
Request sourcing Ask a question