VBA-4E4A-CB1-ZEJ/E2J
AS-Interface printed circuit board module. Printed circuit board module, 4 inputs/4 outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: V3.0. UL File Number...
AS-Interface printed circuit board module. Printed circuit board module, 4 inputs/4 outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: V3.0. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of outputs. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 30 mA (without sensors) / max. 180 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 ... 31 V. Input current: 5 mA (typically). Switching point: according to EN 61131-2 Typ 1. 0 (unattenuated)≤ 0.5 mA1 (attenuated)≥ 2 mA: . 0 (unattenuated): ≤ 0.5 mA. 1 (attenuated): ≥ 2 mA. Signal delay: < 2 ms (input/AS-Interface). Number/Type: 4 electronic outputs, PNP. Supply: from AS-Interface. Voltage: 21 ... 31 V. Current: ≤ 100 mA per output, ≤ 140 mA total. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015: . Directive 2014/30/EU: EN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015. Degree of protection: EN 60529:2000. Fieldbus standard: EN 50295:1999, IEC 62026-2:2015. Input: EN 61131-2:2015. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61326-1:2013. Profile: S-7.A.7. IO code: 7. ID code: A. ID1 code: 7. ID2 code: 7. Data bits (function via AS-Interface): InputOutput. D0 IN1 OUT1D1 IN2 OUT2D2 IN3 OUT3D3 IN4 OUT4: . D0: IN1 OUT1. D1: IN2 OUT2. D2: IN3 OUT3. D3: IN4 OUT4. Parameter bits (programmable via AS-i): function. P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings)P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings)P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings)P3not used: . P0: Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings). P1: Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings). P2: Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings). P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Connection: screw terminals, removable rated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2In case of wire end ferrule with plastic sleeve: 0.25 mm2 ... 0.5 mm2On connection of multiple conductors when using two conductors with the same cross section:Flexible with twin wire end ferrule:. Mass: 90 g. Dimensions: . Height29 mmWidth51 mmLength76 mm: . Height: 29 mm. Width: 51 mm. Length: 76 mm. Tightening torque of clamping screws: 0.22 ... 0.25 Nm
| Brand | Pepperl Fuchs |
| Lifecycle status | active |