VIM32PP-E7DC8-0RE-IO-1V1401
Vibration sensor. Vibration sensor with IO-Link and programmable switching output or analog current output, Series: Performance Plus Line, Measured variable: Vibration velocity <BR>Vibration accelerat...
Vibration sensor. Vibration sensor with IO-Link and programmable switching output or analog current output, Series: Performance Plus Line, Measured variable: Vibration velocity <BR>Vibration acceleration <BR>Bearing status parameter <BR>Crest factor <BR>Temperature, Vibration acceleration: 0 ... 34 g rms, Vibration acceleration: 0 ... 48 g peak value per 1 s, Vibration acceleration: -48 ... 48 g by means of BLOB transfer. Type: Vibration sensor. Measuring technology: MEMS capacitive. Series: Performance Plus Line. Measured variable: Vibration velocity Vibration acceleration Bearing status parameter Crest factor Temperature. Measuring range: . Vibration velocityv-rms0 ... 128 mm/sVibration accelerationa-rms0 ... 34 g rmsVibration accelerationa-Peak0 ... 48 g peak value per 1 sVibration accelerationa-Raw-48 ... 48 g by means of BLOB transferBearing status parameter1 ... 4 see section characteristic curveCrest factor0 ... 100Temperature-40 ... 85 °C (-40 ... 185 °F): v-rms. Vibration velocity: 0 ... 128 mm/s. Vibration acceleration: 0 ... 34 g rms. Vibration acceleration: 0 ... 48 g peak value per 1 s. Vibration acceleration: -48 ... 48 g by means of BLOB transfer. Bearing status parameter: 1 ... 4 see section characteristic curve. Crest factor: 0 ... 100. Temperature: -40 ... 85 °C (-40 ... 185 °F). Measurement accuracy: Vibration velocity: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s Vibration acceleration: ± 0.01 g (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954. Cross-sensitivity: < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis. Resolution: Vibration velocity: 0.01 mm/s Vibration acceleration: 0.01 g Bearing status parameter: 0.01. Frequency range: Vibration acceleration a-raw: 0 ... 12000 Hz , by means of BLOB transfer Vibration velocity rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration a-peak: 10 ... 10000 Hz Crest factor: 10 ... 10000 Hz Bearing status parameter: 10 ... 10000 Hz , acc. to DIN ISO 13373-3. Averaging time: for v-rms: 2 s for a-rms: 2 s. Sampling rate: Vibration acceleration a-raw: 64 kHz , programmable Vibration velocity rms: 8 kHz Vibration acceleration rms: 8 kHz Vibration acceleration a-peak: 32 kHz Crest factor: 32 kHz Bearing status parameter: 32 kHz. MTTFd: 329 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Fusing: external fuse is required: 1 A , fast acting , 30 V DC. Operating voltage: 18 ... 30 V DC. Current consumption: max. 320 mA. Power consumption: max. 10 W. Time delay before availability: ≤ 3.6 s. Surge protection: up to 2 kV. Interface type: IO-Link (via C/Q = Pin 4). IO-Link revision: 1.1. Device profile: Identification and Diagnosis - I&D , BLOB transfer. Process data: Input 24 Byte measurement channels: -rms value velocity - peak value acceleration- rms value acceleration - temperature- crest factor- bearing status parameter per measurement channel: - measurement value 2 Byte - scaling 8 Bit - switching signals 2 Bit status data. Vendor ID: 1 (0x0001). Device ID: 5308673 (0x510101). Transfer rate: COM3 (230.4 kbits/s). Min. cycle time: 3.8 ms. SIO mode support: yes. Compatible master port type: Class A Class B (use 3-pole adapter or 3-wire cable). BLOB size: 1.28 MByte , programmable. BLOB segments: 200 Byte per request and BLOB segment respectively. Output type: C/Q - Pin 4 in SIO mode (switching signal of the measured variable is programmable). Switching function: Normally open/closed (NO/NC). Operating current: ≤ 100 mA. Short-circuit protection: yes. Output type: I/Q - pin 2 (parameterizable as analog current output or switching signal) - I: analog output for the measured variable, current 4 ... 20 mA - Q: switching signal of the measured variable is parameterizable, PNP normally open. Switching function: Normally open/closed (NO/NC). Operating current: ≤ 120 mA for switching signal. Voltage drop: < 2 V. Output current: 4 ... 20 mA at analog output. Load resistor: ≤ 500 Ω at analog output. Short-circuit protection: yes. Degree of protection: DIN EN 60529, IP66, IP67. Shock resistance: DIN EN 60068-2-27, 60 g, 6 ms. Vibration resistance: DIN EN 60068-2-6, 16.5 g, 10 ... 12000 Hz. Vibration evaluation: DIN ISO 10816/20816 , DIN ISO 13373-3. UL approval: . Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestMaximum permissible ambient temperaturemax. 80 °C (max. 176 °F): . Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request. Maximum permissible ambient temperature: max. 80 °C (max. 176 °F). Ambient temperature: -40 ... 85 °C (-40 ... 185 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: plug. Housing material: Stainless steel 1.4305 / AISI 303. Degree of protection: IP66 / IP67 only in connected state. Connector: . ThreadingM12Number of pins4: . Threading: M12. Number of pins: 4. Mass: approx. 100 g. Dimensions: . Length72.5 mmDiameter23.8 mm: . Length: 72.5 mm. Diameter: 23.8 mm
| Brand | Pepperl Fuchs |
| Lifecycle status | active |